hostname DRM
!
redundancy
high-availability
config-sync
!
interface Vlan20
ip address 10.20.1.3 255.255.255.0 alt ip address 10.20.1.2 255.255.255.0
standby ip 10.30.1.4
standby priority 100 alt standby priority 50
no ip redirects
!
interface Vlan30
ip address 10.30.1.3 255.255.255.0 alt ip address 10.30.1.2 255.255.255.0
standby ip 10.30.1.4
standby priority 100 alt standby priority 50
no ip redirects
!
end
For DRM, the average failover time was measured at 2.56 seconds. For SRM, the average failover time was measured at 2.31
seconds. Keep in mind that both DRM and SRM will maintain Layer 3 forwarding entries in the hardware-forwarding table
(a function of the Cisco Catalyst OS High Availability feature). The difference is that DRM employs two active routers in the
chassis and the SRM employs only one router. So SRM requires a routing table recalculation in the software that DRM does
not, but neither has a direct effect on the failover time for Layer 3 traffic.
A second test with one workstation running a File Transfer Protocol (FTP) client and another running an FTP server was run.
Transferring a 10-MB file across the switch at Layer 3 during normal operations took an average of 16 seconds. If a supervisor
switchover takes place during this same FTP session, the transfer time is an average of 18 seconds. During switchover, the
difference in FTP transfer time is only 2 seconds. This example is used to demonstrate a realistic TCP application.
A third test with IP phones connected to the Cisco Catalyst 6500 Series involved establishing an IP phone call between one
local IP phone and one remote IP phone. With the Cisco Catalyst OS High Availability feature enabled, a supervisor engine
switchover was initiated. The IP phone call was maintained through the switchover and the call participants noticed minimal
disruption. This provides a real-world example of the capability of the Cisco Catalyst 6500 to provide high availability in all
layers of the network.
For general purposes, it is still maintained that the Layer 2 and Layer 3 stateful supervisor engine switchover will take place
in less than three seconds to cover most real-world scenarios.
Redundant Power Supplies
Currently the Cisco Catalyst 6500 Series can be configured with a 1000- (6-slot chassis only), 1300-, 2500-, or 4000-watt
power supply. In addition, a power redundancy feature is available to further specify the power configuration via software. By
default, the power redundancy (or load sharing) feature is enabled. With two power supplies installed and power redundancy
enabled, the total power drawn from both supplies is at no time greater than the capability of one supply. If one power supply
fails, the other power supply can take over the load and the complete system remains powered. If power redundancy is