Cisco AP775A - Nexus Converged Network Switch 5010 Note de mise à jour - Page 12

Parcourez en ligne ou téléchargez le pdf Note de mise à jour pour {nom_de_la_catégorie} Cisco AP775A - Nexus Converged Network Switch 5010. Cisco AP775A - Nexus Converged Network Switch 5010 26 pages. Cisco nexus 5000 series release notes release 4.1(3)n1(1) (ol-16601-01 h0, july 2009)
Également pour Cisco AP775A - Nexus Converged Network Switch 5010 : Note de mise à jour (48 pages), Note de mise à jour (44 pages), Manuel de référence rapide (14 pages), Note de mise à jour (26 pages)

Cisco AP775A - Nexus Converged Network Switch 5010 Note de mise à jour

Caveats

S e n d d o c u m e n t a t i o n c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m
Caveats
This section includes the following topics:

Open Caveats

This section lists the open caveats for this release.
Cisco Nexus 5000 Series Release Notes, Release 4.0(1a)N1(1a)
12
Open Caveats, page 12
CSCsy53718
Symptom: If errdisable recovery interval is configured to the maximum value of 65535 (taking
approximately 18hrs), when a port is errdisabled due to a recovery enabled cause, it takes four more
hours for the recovery to take effect.
Workaround: None.
CSCsy05103
Symptom: When an RBAC role is configured to deny a few commands within a specific interface,
the help command falsely displays all commands as denied. This is only a help issue and the rules
are enforced as configured.
Workaround: None.
CSCsy16212
Symptom: When an RBAC role is configured to deny a few commands, users within that role may
incorrectly see a some disallowed commands in the help. This is only a help issue and commands
are denied as per the configured rules.
Workaround: None
CSCsy28374
Symptom: An RBAC role with rules denying commands for all interfaces of certain types using the
wildcard * option, are not honored.
Workaround: Configure rules with specific interface names.
CSCsv81694
Symptom: The auto learn static MAC entry is removed if the port on which the same MAC address
is dynamically learned is flapped. The static MAC address is removed from the software as well as
the hardware.
Workaround: Re-add the static MAC entry through the CLI.
OL-16601-01