Setting
Description
0
function inactive
1
function active
Parameter 61: Power reports - on change
This parameter determines the minimum change in consumed power that will result in sending
new power report to the main controller.
For loads under 50W, the parameter is not relevant and reports are sent every 5W change.
Power reports are sent no often than every 30 seconds.
Size: 2 Byte, Default Value: 15
Setting
Description
0
reports are disabled
1 - 500 change in power in %
Parameter 62: Power reports - periodic
This parameter determines in what time intervals the periodic power reports are sent to the main
controller. Periodic reports do not depend on power change (parameter 61).
Size: 2 Byte, Default Value: 3600
Setting
Description
0
periodic reports are disabled
30 - 32400 report interval in seconds
Parameter 65: Energy reports - on change
This parameter determines the minimum change in consumed energy that will result in sending
new energy report to the main controller.
Size: 2 Byte, Default Value: 10
Setting
0
reports are disabled
1 - 500 (0.01 – 5 kWh) – change in energy
Parameter 66: Energy reports - periodic
This parameter determines in what time intervals the periodic energy reports are sent to the
main controller. Periodic reports do not depend on energy change (parameter 65).
Size: 2 Byte, Default Value: 3600
Setting
Description
Description