always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number
1
2
3
4
5

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further
enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the
desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the
same logic applies: Values greater than 32768 may needed to be given as negative values too.
Parameter 1: Fibaro Smoke Sensor sensitivity
There are 3 levels of sensitivity to smoke presence. Level 1 means the highest sensitivity. Rising the parameter value lowers the sensitivity to smoke presence.
Size: 1 Byte, Default Value: 2
Setting
1
2
3
Parameter 2: Z-Wave notifications status
This parameter allows to activate excess temperature and/or enclosure opening notifications sent to the main controller.
Size: 1 Byte, Default Value: 0
Setting
0
1
2
3
Parameter 3: Visual indicator notifications status
This parameter allows to activate visual indications but does not apply to major alarms, such as FIRE, TROUBLE and LOW BATTERY ALARM.
Size: 1 Byte, Default Value: 0
Setting
0
1
2
4
Parameter 4: Sound notifications status
This parameter allows to activate sound signals but does not apply to major alarms, such as FIRE, TROUBLE and LOW BATTERY ALARM.
Size: 1 Byte, Default Value: 0
Setting
0
1
2
4
Parameter 10: Configuration of control frames in BASIC command class
https://manual.zwave.eu/backend/make.php?lang=en&sku=FIBEFGSD-002
https://manual.zwave.eu/backend/make.php?lang=en&sku=FIBEFGSD-002
Maximum
Description
Nodes
1
Z-Wave Plus Lifeline.
5
Trigger: Smoke alarm - association group, value depends on the configuration. Type of frame sent
by the device when the association group is activated: BASIC_SET.
5
Trigger: Tamper - association group. Type of frame sent by the device when the association group
is activated: NOTIFICATION_REPORT.
5
Trigger: Smoke alarm ZW3 - association group for ZW3 backward compatibility. Type of frame sent
by the device when the association group is activated: SENSOR_ALARM_REPORT.
5
Trigger: Tamper ZW3 - association group for ZW3 backward compatibility. Type of frame sent by the
device when the association group is activated: SENSOR_ALARM_REPORT.
Description
HIGH Sensitivity
MEDIUM Sensitivity
LOW Sensitivity
Description
all notifications disabled
enclosure opening notification enabled
exceeding temperature threshold notification enabled
all notifications enabled
Description
all notifications disabled
enclosure opening notification enabled
exceeding temperature threshold notification enabled
lack of Z-Wave range notification
Description
all notifications disabled
enclosure opening notification enabled
exceeding temperature threshold notification enabled
lack of Z-Wave range notificatio
5/8