Malfunction alarm (Parameter Number 84, Parameter Size 1) Time interval in which malfuntion alarm, if
detected, is repeated using visual and acoustic alarms.
Value
Description
130 — 127
Temperature alarm (Parameter Number 85, Parameter Size 1) Time interval in which temperature alarm, if
detected, is repeated using visual and acoustic alarms.
Value
Description
130 — 127 5 means 500ms
Lack of the Z-Wave range alarm (Parameter Number 86, Parameter Size 2) Time interval in which lack of
the Z-Wave network alarm, if detected, is repeated using visual and acoustic alarms.
Value
Description
1 — 17280 360 means 30min (Default 360)
Low battery alarm (Parameter Number 87, Parameter Size 2) Time interval in which low battery alarm, if
detected, is repeated using visual and acoustic alarms.
Value
Description
1 — 17280 360 means 30min (Default 360)
temperature measurement compensation for report (Parameter Number 88, Parameter Size 1)
Consider temperature measurement compensation (parameter 73) when sending temperature report.
Value
0
0 - ignore temperature compensation (Default)
1
1 - include temperature compensation
Tamper alarm (Parameter Number 89, Parameter Size 1) activates/inactivates temper switch alarm