3. Associations in Z-Wave network Security Mode
This parameter defines how commands are sent in specified associa-
tion groups: as secure or non-secure. Parameter is active only in Z-Wave
network Security Mode. It does not apply to 1st group "Lifeline".
Available settings: 0 - none of the groups sent as secure
Default setting:
11. 2nd association group triggers
Parameter defines events which result in sending on/off commands
to devices added to the 2nd association group.
These commands are sent alternately to switch the devices on and off.
Available settings: 0 - switch after opening and closing
Default setting:
12. Association for opening - value sent
Value sent to devices in 2nd association group when opening is
detected
The value of 0 turns OFF the device, 255 turns it On.
In case of associating devices allowing smooth control, values 1-99
allow to set an associated device to a specified level.
Available settings: 0-99 or 255
Default setting:
13. Association for closing - value sent
Value sent to devices in 2nd association group when closing is
detected
The value of 0 turns OFF the device, 255 turns it On.
In case of associating devices allowing smooth control, values 1-99
allow to set an associated device to a specified level.
Available settings: 0-99 or 255
Default setting:
14. Association for opening - time delay
Time that must elapse from opening to send the command frame to
to devices in 2nd association group.
Available settings: 0-32400 - time in seconds
Default setting:
1 - 2nd group "On/Off" sent as secure
2 - 3rd group "Tamper" sent as secure
3 - 2nd and 3rd group sent as secure
3 (all)
Parameter size:
1 - switch after opening (parameter 12)
2 - switch after closing (parameter 13)
0
Parameter size:
255
Parameter size:
0
Parameter size:
0
Parameter size:
1 [byte]
1 [byte]
2 [bytes]
2 [bytes]
2 [bytes]
ADVAnCED PARAMETERS