9. Motion detection - night/day
This parameter defines the difference between night and day in terms
of light intensity, used in parameter 8.
Available settings: 1-32767 (1-32767 lux)
Default setting:
12. BASIC command class configuration
This parameter determines the command frames sent to 2nd associa-
tion group (assigned to PIR sensor).
Available settings: 0 - BASIC On and OFF command frames sent in
Default setting:
14. BASIC ON command frame value
The command frame sent at the moment of motion detection. Fur-
ther motion detections, during the cancellation time, will not result
in sending the association.
Available settings: 0-255
Default setting:
16. BASIC OFF command frame value
The command frame sent at the moment of motion alarm cancella-
tion, after cancellation delay time specified in parameter 6.
Available settings: 0-255
Default setting:
18. Associations in Z-Wave network Security Mode
This parameter defines how commands are sent in specified associa-
tion groups: as secure or non-secure. Parameter is active only in Z-Wave
network security mode. It does not apply to 1st group "Lifeline".
Available settings: 0 - none of the groups sent as secure
Default setting:
200 (200 lux) Parameter size:
Basic Command Class
1 - only the BASIC On command frame sent in
Basic Command Class
2 - only the BASIC OFF command frame sent in
Basic Command Class
0
Parameter size:
255
Parameter size:
0
Parameter size:
1 - 2nd group sent as secure
2 - 3rd group sent as secure
4 - 4th group sent as secure
8 - 5th group sent as secure
15
Parameter size:
2 [bytes]
1 [byte]
2 [byte]
2 [bytes]
1 [byte]