CONVERGENCE ADJUSTMENT

NO. Adjustment part
Adjusting procedure and conditions
1
CONVERGENCE
1. Receive the "Crosshatch Pattern" signal.
ADJUSTMENT
2. Using the remote controller, call NORMAL
(To be done
mode.
after the purity
adjustment.)
Static convergence
1. Turn the 4-pole magnet to a proper opening
angle in order to superpose the blue and red
colours.
2. Turn the 6-pole magnet to a proper opening
angle in order to superpose the green colour
over the blue and red colours.
Dynamic convergence
1. Adjust the convergence on the fringes of the
screen in the following steps.
a) Fig. 5-1: Drive the wedge at point "a" and
swing the deflection coil upward.
b) Fig. 5-2: Drive the wedge at points "b" and
"c" and swing the deflection coil
downward.
c) Fig. 5-3: Drive the "c" wedge deeper and
swing the deflection coil rightward.
d) Fig. 5-4: Drive the "b" wedge deeper and
swing the deflection coil leftward.
2. Fix all the wedges on the CRT and apply glass
tape over them.
3. Apply lacquer to the deflection yoke lock screw,
magnet unit (purity, 4-pole, 6-pole magnets)
and magnet unit lock screw.
Finally received the Red-only and Blue-only
signals to make sure there is no other colours
on the screen.
Waveform and others
BGR
B
G
R
Fig. 5-1
RGB
R
G
B
Fig. 5-2
RGB
B
G
R
Fig. 5-3
BGR
R
G
B
Fig. 5-4
Wedge "a"
About
About
100°
100°
Lacquer
Wedge
Wedge
"b"
"c"
Fig. 5-5
4-pole magnet
6-pole magnet
CRT neck
20cm
Lacquer
(21")
Purity magnet
40cm
Fig. 5-6
(14")
8-1
CRT CUT-OFF, BACKGROUND AND SUB-CONTRAST ADJUSTMENT
NO. Adjustment part
Adjusting procedure and conditions
1
1. Switch TV to VIDEO mode, BLUE BACK OFF,
CRT CUTOFF
with NO VIDEO signal.
ADJUSTMENT
2. Press R/C to set Picture Normal condition.
(I
2
C BUS
3. Connect the oscilloscope to Red OUT from
CONTROL)
IC801.(TP851 (14")/TP852 (20"/21"))
Range
Sweep
4. Adjust SCREEN VR, so that the tip of signal
reach 3.0 ±0.1 Vdc.
2
1. Call "SUB-BRI" in service mode. (Receive
SUB-
Crosshatch pattern with 5 black level windows)
BRIGHTNESS
2. Adjust the "SUB BRIGHT" bus data in order
ADJUSTMENT
that the line 1, 2 and 3 have the same darkness
(I
2
C BUS
wherelse line 4 is slightly brighter than line 1,
CONTROL)
2 and 3 and finally line 5 will be the brighter
than line 4.
3
WHITE
1. Receive the "WHITE" pattern with BURST sig-
BALANCE
nal.
SERVICE
2. Press R/C to set Picture NORMAL condition.
3. Connect the DC miliammeter between TP602
MODE
(-) and TP603 (+).
ADJUSTMENT
4. Check Beam current should be around 1,100 µA
(I
C BUS
2
(20"&21") (14" around 800 µA).
CONTROL)
5. Set it to service mode and adjust the DRI-GS,
& DRI-BS data to have a colour temperature
of 12,300°K or 7,500°K (white).
* Note .
6. Receive "WHITE" pattern, WITH BURST signal,
and set BRIGHTNESS Y by generator, to ** 10
cd/m2 (MINOLTA CA-100) by reducing
LUMINATE Y signal.
7. Adjust "CUT-R" & "CUT-G" to get desired colour
temperature. Then go back NORMAL mode
(HIGH BRIGHT**) to check colour temperature.
If out 14" back to (1)
Note: This adjustment must be done after
warming up the unit for 30 minutes
or longer with a beam current over
µ
700
A. (20"&21")
(For 14", the beam current should be
µ
over 500
A)
* Adjust DRI-GC/GW, DR-BC/BW as following
data, after finishing DRI-BS and DRI-GS data
adjustment.
DRI-RW=32 (FIXED), DRI-GW="DRI-
GS"-7*, DRI-BW="DRI-BS"-7*
DRI-RC=25, DRI-BC="DRI-BS",
DRI-GC="DRI-GS"-7*
4
MAXIMUM
1. Receive the "Monoscope Pattern" signal.
2. Press R/C to set Picture NORMAL condition.
BEAM CHECK
3. Connect the DC miliammeter between TP603
(+) and TP602 (–).
(Full Scale: 3 mA Range)
4. Beam current must be within 1,100 ±100µA
(21") 800 ± 100 µA(14") .
Waveform and others
3.0Vdc
: 1 V/Div (DC)
: 5 msec/Div
1 V
0
Fig. 6
1 2 3 4 5
1, 2 and 3 are in same black level.
Fig. 7
Refer to Page ????.
* 12,300°K
X : 0.272
Y : 0.275
* 18,000°K
X : 0.255
Y : 0.255
(MINOLTA COLOUR ANALYZER
CA-100)
*Note: Above Data can be UP/
DOWN by Volume key.
LOW
HIGH
14"
10 cd/m2
200 cd/m2
20"/21" 10 cd/m2
120 cd/m2
* 12,300°K DRI-GW="DRI-GS"-7
DRI-BW="DRI-BS"-7
* 18,000°K DRI-GC="DRI-GS"
DATA-5
DRI-RC=27
8-2