Sharp AR-AR-M355N Manuel de référence rapide - Page 7

Parcourez en ligne ou téléchargez le pdf Manuel de référence rapide pour {nom_de_la_catégorie} Sharp AR-AR-M355N. Sharp AR-AR-M355N 31 pages. Digital multifunctional imager

Simulation List (Main/Sub)
8
1
Used to check and adjust the operations of the developing voltage of each color and the control circuit.
2
Used to check and adjust the operation of the main charger grid voltage in each printer mode and the control circuit.
6
Used to check and adjust the operation of the transfer voltage and the control circuit.
17
Used to check and adjust the operation of the transfer voltage and the related circuit. (Transfer belt cleaning mode.)
9
1
Used to check and adjust the operation of the load (clutch/solenoid) in the duplex section and the control circuit.
2
Used to check the operations of the sensors and detectors in the duplex section and its control circuit.
10
1
Used to check the operations of the toner motor and the related circuit.
13
0
Used to cancel the self-diag "U!" trouble. (Only when FAX is installed.)
14
0
Used to cancel excluding the self-diag U1/LCC/U2/PF troubles.
15
0
Used to cancel the self-diag "U6-01, 02, 03, F3-12, 22" (large capacity paper feed tray, paper feed trays 1, 2) troubles.
16
0
Used to cancel the self-diag U2 troubles.
17
0
Used to cancel the PF troubles (when the copy inhibit command from the host computer is received).
21
1
Used to set the maintenance cycle.
22
1
Used to check the print count value in each section an each operation mode. (Used to check the maintenance timing.)
2
Used to check the total numbers of misfeed and troubles. (When the number of misfeed is considerably great, it is judged as
necessary for repair. The misfeed rate is obtained by dividing this count value with the total counter value.)
3
Used to check misfeed positions and the misfeed count of each position. (if the misfeed count is considerably great, it may be
judged as necessary to repair.)
4
Used to check the trouble (self-diag) history.
5
Used to check the ROM version of each unit (section).
6
Used to output the list of the setting and adjustment data (simulations, FAX soft switch, counters).
7
Used to display the key operator code. (This simulation is used when the customer forgets the key operator code.)
8
Used to check the number of use of the finisher, the SPF, and the scan (reading) unit.
9
Used to check the number of use (print quantity) of each paper feed section.
10
Used to check the system configuration (options, internal hardware).
Quick Reference Guide: AR-M355N/M455N
Simulation List (Pg. 2 of 10)
7