Network (Web Page)

1. Open a web browser and enter the following URL :-
2. To access the Service Webpage, enter the "Service" Username and Password.
Click Login:-
Note: If User Authentication is enabled, open the device webpage and login by selecting "Service"
from the drop down menu and entering the service password:-
3. When the service webpage opens, click Update of Firmware.
4. Click Browse to navigate to the location of the updated firmware file and select
Open.
5. Press Execute to start the firmware update.
Firmware Upgrade
Firmware update is complete.
http://ipaddress/service_login.html or
http://ipaddress/service_account.html
Example:
http://192.168.0.1/service_login.html
Default Username:
Password:
service
service