Sharp Notevision XG-C455W Manuel de configuration

Changing the Lens

Info
• Before changing the lens, turn off the power of the projector and remove the power cord from the wall
outlet.
• Do not attempt to change the lens while the projector is mounted on the ceiling.
1
Remove the lens housing cover
by using the supplied lens hous-
ing cover removal tool to push
down on the groove on the lens
housing cover.
• Hold down the lens housing cover with
your hand to prevent it from flying out.
2
Slide the lens fastener catch tab
in the direction of "UNLOCK"
while holding the lens to prevent
it from falling out.
• Slide the lens fastener catch tab until the
window located beside "LOCK" comes to
the top. Look inside the window to make
sure that the two grooves on the lens fas-
tener ring are facing up.
3
Remove the lens by pulling it
straight out.
4
Remove the protection cap from
the back of the new lens.
Lens fastener catch tab
Two grooves
Window
-9