Digital Acoustics SPKR-IP-CS Manuel de démarrage - Page 3

Parcourez en ligne ou téléchargez le pdf Manuel de démarrage pour {nom_de_la_catégorie} Digital Acoustics SPKR-IP-CS. Digital Acoustics SPKR-IP-CS 3 pages.
Également pour Digital Acoustics SPKR-IP-CS : Manuel de démarrage (4 pages)

Digital Acoustics SPKR-IP-CS Manuel de démarrage
Select the SIP Settings tab
• Press the Apply Defaults button on the bottom right to copy in the
default SIP information that was previously setup
• Enter the SIP Extension, SIP Password (also known as the
Secret) that have been setup on the SIP based phone system for
this IP7 device
• In the SIP Authentication (also known as the SIP Authorization
Name), enter the User that has been associated with this extension
in the SIP based phone system. If no User has been setup, use the
same value as the SIP Extension
• Check the Full Duplex option to enable full duplex operation using
the integrated microphone in the SPKR-IP-CS or leave it blank for of
half duplex or speaker only operation
o
In a half-duplex phone call, one party has their microphone
active while the other party has their speaker active. By default,
when a call is initiated, the SPKR-IP-CS starts with the speaker
active and the phone operator starts their microphone active. The
phone operator can toggle the modes by pressing 0 on the phone's
keypad. In half duplex mode, the volume will always be louder, and
the microphone gain will always be higher
In full duplex mode, both parties have their speaker and microphone
o
active at the same time. In full duplex mode, the SPKR-IP-CS
volume will always be softer, and the microphone gain will always
be lower. This is due to the algorithms used by the IP7 for echo
cancellation
Select the Advanced Settings tab
• Click the Set button next to Audio Profile and select the SPKR-IP-
CS Full Duplex audio profile if using full duplex. Otherwise select
the Half Duplex audio profile
• Click the Save Settings button. The endpoint will reboot with the
changes and register with the SIP Server within 30 seconds. The
green Ready LED on the panel will blink rapidly for 30 seconds and
then turn solid
• There are 7 volume steps that will vary based on whether full or half
duplex has been configured. Volume can be adjusted by pressing
the Vol+ and Vol- buttons (connectors 9 and 10) or when a SIP call is
in progress by pressing:
o #00 – Set volume down one level
o #01 – Set volume level to 1
o #02 – Set volume level to 2
o #03 – Set volume level to 3
o #04 – Set volume level to 4
o #05 – Set volume level to 5
o #06 – Set volume level to 6
o #07 – Set volume level to 7
o #08 – Set volume up one level
IP7 and Digital Acoustics® are trademarks of Digital Acoustics LLC.
Other trademarks are the property of their respective owners.
All Rights Reserved ©2019
www.digitalacoustics.com/support
Page 3 of 3
Digital Acoustics SPKR-IP-CS
Installation and SIP Configuration