ure
Step1
config
Step2
interface intf-type intf-id
Step3
ethernet
{supported | timeout seconds}
Step4
exit
Step5
exit
Step6
ethernet
{start | stop} interface intf-type
intf-id
The remote OAM loopback cannot be enabled on the physical interface that
belongs to the aggregation interface.
1.3.3 Configuring OAM Link Monitoring
You can configure the low threshold and the high threshold of OAM link
monitoring.
The procedure to configure the OAM link monitoring on an interface is shown in
the following table:
Procedure
Step1
config
Step2
interface intf-type intf-id
Step3
ethernet
supported
Step4
ethernet
symbol-period {threshold {high
{
symbols
{symbols}} | window symbols}
http://www.level1.com
oam
remote-loopback
oam
remote-loopback
Command
oam
link-monitor
oam
link-monitor
|none}
|
low
Enters the global configuration mode.
Enters the interface configuration mode.
Configures optional loopback parameters from the
remote OAM:
l
The supported parameter is used to enable
an interface to support the remote loopback of
Ethernet OAM. Remote loopback is not
supported by default.
l
The timeout parameter is used to configure
the timeout time of remote loopback. It ranges
between 1 and 10 and its default value is 2.
Exits from interface configuration mode.
Exits from the global configuration mode.
Enables or disables remote loopback on an
interface.
Purpose
Enters the global configuration mode.
Enters the interface configuration mode.
Enables link monitoring on an interface. The link
monitoring is supported by default.
Sets the high and low threshold of the periodical
event of the error signal, which triggers the error
link events.
The threshold high parameter is used to configure
the high threshold. Its unit is signal number. It
ranges between 1 and 65535 and its default value
is none.
The threshold high parameter is used to configure
the low threshold. Its unit is signal number. It ranges
between 0 and 65535 and its default value is 1.
The window parameter is used to configure the
window size of the round-query period. The unit of
the window size is the number of the 100M signal.
OAM Configuration
- 6 -