➢ The power cord should always be connected to the power source through a plug socket
with a grounding pin . It is allowed to connect to a network without a neutral pin, provided
that the earth is connected to the earth terminal located on the screw connection.
➢ It is unacceptable to use earthing and zeroing at the same time through the mains
cable.
➢ Double fuse - pole/neutral. Each mains cable (L, N) is protected by a separate fuse
located inside the device. If only one of the fuses fails, the other components may remain
energized.
➢ Some elements of the power supply located on the printed circuit board inside the
device are at the mains potential.
➢ To avoid contact with live parts, always disconnect the power supply before removing
the housing cover.
➢ The device does not have a built-in disconnection system. Such a system should be
located outside the device.
➢ If the device is powered from the 230 V mains, the plug on the power cord serves as a
disconnecting element and the plug socket should be located near the device and be easily
accessible for service.
The manufacturer is not responsible for any events resulting from the use and installation of
the device not in accordance with the instruction manual.
The instruction manual is an integral part of the device and is handed over to the users
together with it.
8.3 Data Transmission
The data transmission functions and parameters of the device's communication interfaces are
defined by the following standards and recommendations:
✓ IEEE 802.3 10Base-T Ethernet
✓ IEEE 802.3u 100Base-TX Fast Ethernet
✓ IEEE 802.3u 100Base-FX Fast Ethernet Fiber
✓ IEEE 802.3ab 1000Base-T
✓ IEEE 802.3z Gigabit Fiber
✓ IEEE 802.3x Flow Control and Back pressure
✓ IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
✓ IEEE 802.1p Class of Service (CoS)
✓ IEEE 802.1Q VLAN
✓ IEEE 802.1ad QinQ
✓ IEEE 802.1D- Spanning Tree Protocol (STP)
✓ IEEE 802.1D-2004 Rapid Spanning Tree Protocol (RSTP)
✓ IEEE 802.1s Multiple Spanning Tree Protocol (MSTP)
✓ IEEE 802.3ad Link Aggregation Protocol (LACP)
✓ IEEE 802.1x Port Based Network Access Protocol
✓ IEEE 802.3az EEE
✓ IEEE 802.3af/ at type 1/2 up to 30W
REV.
1.19
HYPERION-300 quick guide
Hyperion 30x manual
https://bitstream.pl
2023.04.05
7_ 8