Également pour Siemens SIMATIC ET 200SP : Manuel (40 pages), Manuel de l'utilisateur (21 pages), Manuel (34 pages), Manuel (48 pages), Manuel (30 pages), Manuel (34 pages), Informations sur le produit (38 pages), Manuel (37 pages), Manuel (36 pages), Manuel (44 pages), Manuel (31 pages), Manuel (35 pages), Manuel (23 pages), Manuel de configuration (20 pages), Manuel (34 pages), Manuel (29 pages), Manuel (33 pages), Manuel (31 pages), Manuel de l'utilisateur (32 pages), Manuel (31 pages), Manuel (28 pages), Manuel (41 pages), Manuel (32 pages), Manuel (49 pages), Manuel (24 pages), Manuel (34 pages), Manuel (41 pages), Manuel (30 pages), Manuel (31 pages), Manuel (27 pages), Manuel (24 pages), Manuel (24 pages), Manuel (49 pages), Manuel (40 pages), Manuel (38 pages), Manuel (39 pages), Informations sur le produit (24 pages), Manuel (32 pages), Informations sur le produit (10 pages), Manuel de l'équipement (43 pages), Manuel (33 pages), Manuel de l'équipement (44 pages), Mode d'emploi original (6 pages), Manuel (35 pages), Manuel (28 pages), Manuel de l'équipement (32 pages), Manuel (50 pages), Manuel (30 pages), Manuel (26 pages), Manuel (28 pages), Manuel (34 pages), Manuel (44 pages), Manuel (33 pages), Manuel de l'équipement (42 pages), Manuel d'instructions original (16 pages)

Siemens SIMATIC ET 200SP Manuel
Table 4- 1
Settable parameters and their defaults (GSD file)
Parameters
Diagnostics
No supply voltage L+
Diagnostics
Short-circuit to ground
Diagnostics
wire break
1
Operating mode
Input delay
Potential group
If you use a simple switch, you need to connect a resistor in parallel so that the wire break diagnostics is
1
enabled in the open state (sensor resistance for the wire break diagnostics: 25 kΩ to 45 kΩ).
Due to the limited number of parameters at a maximum of 244 bytes per ET 200SP station with a
2
PROFIBUS GSD configuration, the configuration options are restricted. If required, you can assign these
parameters using data record 128 as described in the "GSD file PROFINET IO" column (see table above).
The parameter length of the I/O module is 16 bytes.
DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0)
Manual, 07/2014, A5E03574157-AC
Value range
Disable
Enable
Disable
Enable
Disable
Enable
Channel disabled
Channel enabled
none
0.05 ms
0.1 ms
0.4 ms
0.8 ms
1.6 ms
3.2 ms
12.8 ms
20 ms
Use potential group of the
left module
Allow new potential group
Default
Configuration
in RUN
Disable
yes
Disable
yes
Disable
yes
Channel
yes
enabled
3.2 ms
yes
Use potential
no
group of the
left module
Parameters/address space
4.1 Parameters
Effective range
with configuration software,
e.g. STEP 7 (TIA Portal)
GSD file
GSD file
PROFINET IO
PROFIBUS DP
Module
Module
Module
Module
Module
Module
Channel
Channel
Channel
Module
Module
Module
2