"Button Pressed" event message
This event message is sent after the F1 function key has been pressed or released. If you want
to adapt the short/long press functionality, you need to change the parameter involved in the
configuration file, "RTLS_LM_DataExport.ini".
URI
Parameter
The following happens when you briefly press the F1 function key:
Value
0
1
The default value is 1 in the configuration file "RTLS_LM_DataExport.ini".
SIMATIC RTLS4084T
Operating Instructions, 04/2021, C79000-G8976-C626-02
"agilion.wls.epaper.button_pressed"
Consists of:
TransponderID, type: UInt64
ButtonID, type: UInt32
ButtonDown, type: UInt32
Description
Evaluated as not pressed
OnShortButtonPress = 0
Function key briefly pressed > Event parameter: ButtonDown = 0
Function key pressed long (> 2 seconds) > Event parameter: But-
tonDown = 1
After a short or long press and subsequent heartbeat > Event parame-
ter: ButtonDown = 0
Considered pressed
OnShortButtonPress = 1
Function key pressed short or long > Event parameter: ButtonDown = 1
After a short or long press and subsequent heartbeat > Event parame-
ter: ButtonDown = 0
Programming interface