Siemens Simatic S7-1500 Manuel de l'utilisateur - Page 33

Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Siemens Simatic S7-1500. Siemens Simatic S7-1500 44 pages. Digital output module dq 16x230vac/2a st relais (6es7522-5hh00-0ab0)
Également pour Siemens Simatic S7-1500 : Manuel (40 pages), Manuel (37 pages), Manuel (47 pages), Manuel (24 pages), Manuel (34 pages), Manuel de l'utilisateur (45 pages), Manuel (27 pages), Manuel de configuration (20 pages), Manuel (47 pages), Manuel (43 pages), Manuel (48 pages), Manuel (26 pages), Manuel (28 pages), Manuel (50 pages), Manuel (34 pages), Manuel (50 pages), Manuel (30 pages), Manuel (41 pages), Manuel (50 pages), Manuel (40 pages), Programmation de la sécurité Manualline (48 pages), Manuel d'instructions pour la communication (36 pages), Manuel (40 pages), Manuel (25 pages), Manuel (42 pages), Description de l'application (50 pages), Manuel (28 pages), Manuel (33 pages), Manuel (49 pages), Manuel (36 pages), Manuel (41 pages), Manuel (46 pages), Manuel (38 pages), Manuel (35 pages), Manuel (39 pages), Manuel (28 pages), Manuel (35 pages), Manuel de l'équipement (35 pages), Manuel (50 pages), Manuel de l'équipement (32 pages), Manuel de l'équipement (38 pages), Manuel (29 pages), Manuel de l'équipement (38 pages), Manuel (34 pages), Manuel (36 pages), Manuel de l'équipement (50 pages), Manuel (45 pages)

Siemens Simatic S7-1500 Manuel de l'utilisateur
Technical specifications
Article number
Potential separation
Potential separation channels
between the channels
between the channels, in groups of
between the channels and backplane bus
Isolation
Isolation tested with
Standards, approvals, certificates
Suitable for safety-related tripping of standard
modules
Highest safety class achievable for safety-related
tripping of standard modules
Performance level according to ISO 13849-
1
Category according to ISO 13849-1
SILCL according to IEC 62061
Ambient conditions
Ambient temperature during operation
horizontal installation, min.
horizontal installation, max.
vertical installation, min.
vertical installation, max.
Decentralized operation
Prioritized startup
Dimensions
Width
Height
Depth
Weights
Weight, approx.
Residual current at signal state "0":
Note
Due to the Diagnostics: Wire break function, there is a low level of residual current in the "0"
signal state at the output, which may cause the display diodes to flicker.
This residual current does not depend on the setting for the wire break diagnostics
parameter.
32
6ES7522-1BH01-0AB0
No
8
Yes
707 V DC (type test)
Yes; From FS02
PL d
Cat. 3
SILCL 2
0 °C
60 °C
0 °C
60 °C
Yes
35 mm
147 mm
129 mm
230 g
Digital output module DQ 16x24VDC/0.5A HF (6ES7522-1BH01-0AB0)
Manual, 06/2018, A5E35683409-AC