Également pour Siemens SINAMICS S120 : Manuel d'utilisation (20 pages), Pour commencer (32 pages), Manuel (41 pages), Manuel (43 pages), Instructions pour l'installation dans les armoires pour les applications de propulsion marine (28 pages), Manuel d'application (34 pages), Manuel d'application (46 pages), Manuel d'utilisation (22 pages), Pour commencer (32 pages), Manuel d'utilisation (21 pages), Manuel d'ingénierie (30 pages), Manuel de mise en service (20 pages)

Siemens SINAMICS S120 Brève description
2 Explanation of the Blocks
2.3 FB13 "Drive_FB"
Interface Description
Table 2-7: Interface of FB13 "Drive_FB"
Parameter
ON_OFF1
No_OFF2
No_OFF3
Acknowledge_Faults
Reference_speed
n_Setpoint
Input_Address
Output_Address
Rdy_For_Switching_On
Operation_Enabled
Ctrl_Request
Alarm_Present
Fault_Present
Alarm_Code
Fault_Code
n_Actual_Value
Retval_RD
Retval_WR
All of the above input parameters have an initial value of 0 or FALSE.
Access to the individual STW1 bits – with the exception of ON_OFF1, No_OFF2,
No_OFF3 and Acknowledge_Faults – is not supported by FB13.
SINAMICS S120 at S7-300/400F
Entry-ID: 68624711,
V1.1,
Data
type
Input parameters
Bool
Bool
Bool
Bool
Real
Real
Word
Word
Output parameters
Bool
Bool
Bool
Bool
Bool
Int
Int
Real
Int
Int
12/2014
Description
The drive is switched on with a rising edge at
ON_OFF1.
Requirements:
No_OFF2 and No_OFF3 must already be TRUE
beforehand.
no fault must be pending.
No safety function must have triggered.
With falling edge the motor coasts to a halt.
Emergency stop of the motor with falling edge
Pending faults of the drive are acknowledged with
rising edge.
Reference speed of the drive [1/min] (p2000 of the
respective drive)
Speed setpoint [1/min]
SERVO I/O input address
(from HW Config or STARTER)
SERVO I/O output address
(from HW Config or STARTER)
Drive ready for switch-on.
The drive is in operation.
Control to PLC requested.
The drive object is ready for taking over.
SERVO: alarm pending.
SERVO: fault pending.
Alarm code of a pending SERVO alarm.
Error code of a pending SERVO fault.
Actual speed [1/min].
Error information of SFC14
(output parameter RET_VAL of SFC14)
Error information of SFC15
(output parameter RET_VAL of SFC15)
12