Technical specifications

Note
Siemens makes every attempt to ensure the accuracy of these specifications but reserves the
right to change them at any time.
8.1

Power

12 to 30 V DC (at terminal blocks), 0.1 A surge
loop current
8.2

Performance

Range
Beam angle
Temperature
compensation
8.3

Interface

Display
Programming
Memory
32
4 to 20 mA max
0.25 to 5 m ( 0.8 to 16.4 ft ) (liquids only)
12° at -3 dB boundary
built-in to compensate over the operating range
liquid crystal
three 9 mm (0.35") digits for reading of distance between sensor face and material
multi-segment graphic for commissioning and troubleshooting
2 tactile buttons
non-volatile EEPROM, no battery required