Ordering Data

Order No.:
7MH4 103 -
Nominal load:
10 kg
20 kg
50 kg
100 kg
200 kg
1)
350 kg
Explosion protection
Without
With degree of protection EEx ib II C T6 for
connection to intrinsically-safe circuits
Order No.:
7MH4 105 -
Nominal load:
500 kg
1 t
2 t
5 t
Explosion protection
Without
With degree of protection EEx ib II C T6 for
connection to intrinsically-safe circuits
Order No.:
7MH5 101 -
connecting cable
Nominal load:
60 kg Length
130 kg
280 kg
500 kg
1 t
2 t
3,5 t
5 t
10 t
13 t
28 t
60 t
Explosion protection
Without
With degree of protection EEx ib II C T6 for
connection to intrinsically-safe circuits
SIWAREX R Load Cells Operating Manual
A5E00159640
BB series
Verification capability to
OIML R60 up to 3000 d,
4)
Connecting cable3 m
(4-wire)
C
1
2
A
2
D
2
K
3
A
3
D
3
G
0
1
SB series
Verification capability to
OIML R60 up to 3000 d,
4)
Connecting cable5 m
(4-wire)
C
1
3
K
4
A
4
D
4
K
0
1
RN series
Verification capability to
OIML R60 up to 3000 d,
Connecting cable
(4-wire)
D
0
4)
: 3 m
2
Q
3 m
3
D
3 m
3
J
3 m
3
P
3 m
4
A
5 m
4
G
5 m
4
L
5 m
4
P
5 m
5
A
10 m
5
D
10 m
5
J
15 m
5
Q
0
1
Order No.:
7MH4 106 -
connecting cable
Nominal load:
10 t Length
25 t
40 t
60 t
2)
100 t
Explosion protection
Without
With degree of protection EEx ib II C T6 for
connection to intrinsically-safe circuits
Order No.:
7MH3 105 -
connecting cable
Nominal load:
2,8 t
Length
6 t
13 t
28 t
60 t
130 t
280 t
Order No.:
7MH4 107 -
Connection cable
Nomnal load:
6 kg Length
12 kg
Explosion protection
Without
With degree off protection EEx ib II C T6 for
connection to intrinsically-safe circuits
1)
Mounting accessories on request.
2)
Verification capability to OIML R60 up to 1000 d.
3)
Cables heat-resistant: -60 °C to +180 °C.
4)
Length tolerance: +/- 100 mm; cable length 20 m or more:
+/- 300 mm.
Furhter models of load cells on inquiry.
CC series
Verification capability to
OIML R60 up to 3000 d,
Connecting cable
(4-wire)
1
4)
: 10 m
5
A
C
20 m
5
E
C
20 m
5
H
C
20 m
5
L
C
20 m
6
A
A
0
1
K series
Accuracy class 0.2,
Without explosion protection,
3)
connecting cable
(4-wire)
C0
4)
: 5 m
2
A
5 m
3
A
10 m
1
B
10 m
2
B
10 m
3
B
10 m
1
C
10 m
2
C
SP series
Verification capability to
OIML R60 up to 3000 d,
Connecting cable
(6-wire)
C
0
4)
: 7 m
1
L
7 m
2
B
0
1
34