Installation

5.2 Installing the compact installation unit

Result
Figure 5-4
As long as you do not loosen the hexagon nuts on the top plate, the compact mounting unit with
the load cell is in the installation state. A distance of approximately 3 mm is set between the load
and the load cell. The load cell is not loaded and protected against an overload due to the
assembly.
5.2.6
Installing the compact installation unit
Procedure
Note
Overload of the top plate
When you drag a warped bracket plate with the mounting bolts against the base or top plate, the
fixing of the top plate can be overloaded. Some of the top hexagon nuts below the top plates
cannot be loosened.
• Do not drag a warped bracket plate with the bolted connections against the base or top plate.
• Make sure that the base and top plates are not concave in the center.
1. Remove the bolted connections of the load cell dummies.
2. Raise the load bearing implement at the first bracket.
3. Remove the load cell dummy.
4. Insert the compact mounting unit.
5. Screw in the mounting bolts loosely.
6. Install all of the additional compact mounting units as described in 1 - 6.