Siemens SIWAREX WL270 CP-S SA Manuel d'utilisation - Page 21
Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} Siemens SIWAREX WL270 CP-S SA. Siemens SIWAREX WL270 CP-S SA 38 pages. Mounting plates cp-s sa
Également pour Siemens SIWAREX WL270 CP-S SA : Manuel d'utilisation (40 pages)
5.2
Installing mounting plates
5.2.1
General installation information
The installation conditions vary widely. The dead load of the load bearing implement can be
very low or relatively high. You might be dealing with a container, platform or a roller
conveyor. The following installation instructions can therefore only describe the general
procedures.
Always set up the load bearing implement on dummies in order to protect the load cells from
damage during installation.
The load bearing implement then only has to be raised a few millimeters from bracket to
bracket in order to position the load cell, pressure piece set and mounting plates. The
following description of the installation is based on this assumption.
Note
Maintenance-friendly design
When planning the layout, ensure that the load cells are easily accessible once they are
installed.
Depending on the installation conditions, the detailed procedure may deviate from the
following description.
5.2.2
Overview
The following actions are required to install the mounting plates.
1. Preparing the load cell and pressure piece set
2. Preparing the mounting plates
3. Installing the load cell, pressure piece set and mounting plates
4. Checking the installation
The actions are described in detail in the following.
See also
Safety information/instructions (Page 19)
CP-S SA
Operating Instructions, 04/2009, A5E02522341B
Installation
5.2 Installing mounting plates
21