Siemens 5WG1 584-2AB41 Informations techniques sur les produits - Page 2

Parcourez en ligne ou téléchargez le pdf Informations techniques sur les produits pour {nom_de_la_catégorie} Siemens 5WG1 584-2AB41. Siemens 5WG1 584-2AB41 6 pages. Display and control unit

Siemens 5WG1 584-2AB41 Informations techniques sur les produits
GAMMA instabus
Technical Product Information
March 2008
DELTA profil
Display and control unit
DELTA style
Display and control unit
DELTA ambiente
Display and control unit
With the help of ETS, the application programs can be
selected and the specific parameters and addresses can
be assigned.

Application programs

01 07 Graphical display unit 801501
(for ETS2 version 1.2 or later)
01 07 Graphical display unit 801502
(for ETS3 version 1.0 or later)
• The graphical display unit can indicate up to 16 dif-
ferent messages about the states of bus devices using
various fonts or symbols and can also actively modify
these states.
• The display unit has backlighting as well as a buzzer.
Both the backlighting and the buzzer can be set, op-
tionally active or passive mode.
• In the event of an alarm, a signal is sent on the bus
and the selected message simultaneously flashes in
the centre of the display unit (the frequency can be
set).
Note:
The application programs can be used only with ETS2
version 1.2 or later versions of the ETS.

Installation instructions

• The device can be used for fixed installations, in dry
interior spaces and for integration into a flush socket.
V
DANGER
• The device may only be installed and commissioned
by an authorized electrician.
• The device may not be inserted in the same box as
230 V devices.
• The device may be used in switch sockets, if VDE
approved devices have been used.
• The prevailing safety and accident regulations must
be observed.
• The device may not be opened.
• For planning and construction of electric installations,
the relevant guidelines, regulations and standards of
the respective country are to be considered.
Technical Manual
Update: http://www.siemens.com/gamma
2.3.1.2/2
UP 585
UP 584
UP 586

Technical data

Power supply
• via the bus line
Operating elements
• 2 push buttons for operating the display function
• 2 push buttons for operating the selectable bus func-
tions
• 1 learning button under the cover for toggling be-
tween normal mode / addressing mode
Display elements
• LC display (contains green/yellow backlighting which
can be switched on and off via software)
• 1 red LED for checking the bus voltage and for dis-
playing normal mode / addressing mode
Number of messages
• 16 (freely selectable)
Number of characters per message
• up to 30 characters per line depending on the font
• up to 3 lines
Alarm functions
• priority display of alarm messages
• optical display (flashing)
• acoustic signal (signal tone)
• acoustic feedback via push button action
Connections
• KNX/EIB bus terminal
Mechanical data
• Housing: plastic
• Dimensions (L x W x D):
Display unit UP 584, UP 585, UP 586:
-
65 x 65 x 20 mm (without spring)
65 x 65 x 33 mm (including spring)
Driver: 71 x 71 x 16 mm
-
• Weight: approx. 100 g
• Fire load: approx. 1500 kJ ± 10 %
• Installation: The display unit is mounted on the rele-
vant bus driver module. It cannot be plugged onto the
standard type of bus coupler and no other operator
interfaces can be operated on the driver.
UP 58x, 6 pages
© Siemens AG 2008
Subject to change without prior notice
5WG1 585-2AB_1
5WG1 584-2AB_1
5WG1 586-2AB_1
Siemens AG
Automation and Drives Group
Electrical Installation Technology
P.O. Box 10 09 53, D-93009 Regensburg