Con guring the Motion Sensor

NOTE:
The sensor has a few con gurable parameters which determine its behaviour. The
con gurable parameters related to the Motion Sensor are:
a)Mode Timeout - used in mode 2 to turn the sensor o for time speci ed in
this parameter in seconds, after motion detection.
b) Switch O Time – this timeout (in seconds) will start running as soon
as Mode Timeout is nished. Motion sensor is turned on and when move
ment is detected again the Mode Timeout will start running all over again.
When Switch O time is nished a basic o message is sent to the associated
controller (e.g. Vera) or node (e.g. light switch).
c) The Mode - The mode that is entered after detection.
Mode 1: no detection possible. Battery save mode.
Mode 2: normal operation mode: send on after detection and o
after given time no detection.
Mode 3: Z-Wave chip is always on for con guration purpose. If
mode is 0 or higher then 3, that value will be reported for
get commands, but the sensor will be run as mode 2.
d) Sensitivity - the sensitivity of the motion circuit. Value range is 0-127,
where 0 is least sensitive
1. Open settings box for "_Motion Sensor" in Vera dashboard. Go to "Device Options" tab.
2. Click on "Add con guration settings". Fill out the elds:
a. "Variable" – type "2"
b. "Data Size" – choose
"2 byte
c. "Desired Value" – type required
3.
Click on "Add con guration settings". Fill out the elds:
a.
"Variable" – type "3"
b. "Data Size" – choose
"2 byte
c. "Desired Value" – type required
4. OPTIONAL for Mode selection. Click on "Add con guration settings". Fill out the elds:
a. "Variable" – type "5"
b. "Data Size" – choose
"1 byte
c. "Desired Value" – type "2"
5. OPTIONAL for Sensitivity selection. Click on "Add con guration settings". Fill out the
elds:
a. "Variable" – type "4"
6
hex"
Mode Timeout
value, e.g. 1
hex"
Switch O Time
value, e.g. F
hex"
b. "Data Size" – choose
"1 byte
c. "Desired Value" – type required -,value, e.g. 64
6. Click SAVE in Vera and wait till new settings are saved in Vera.
7. Press the temper button on the device and keep it for 3-7 seconds, then release. This is to
wake up and propagate the settings.
8. Check the con gured values in the eld "Con guredVariable" or "VaraiblesGet" elds on
"Advance Tab" in the Seetings box of the "_Motion Sensor".
Your Motion Sensor is set up.
Example
In this example we set up the following parameters for Motion Sensor:
a.
Mode TimeOut = 1 sec
b.
Switch O time = 15 sec
c.
Mode = 2 (normal operations)
hex"