Siemens CB634GB 3 Series Manuel de l'utilisateur et instructions d'installation - Page 29
Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur et instructions d'installation pour {nom_de_la_catégorie} Siemens CB634GB 3 Series. Siemens CB634GB 3 Series 32 pages.
Également pour Siemens CB634GB 3 Series : Manuel de l'utilisateur et instructions d'installation (32 pages)
Hob type
Induction hob
Full-surface induction hob
Gas hob
Electric hob
22.5 Installation in a tall unit
Observe the installation dimensions and the installation
instructions when installing in a tall unit.
¡ To ventilate the appliance, the intermediate floors
must have a ventilation cut-out.
¡ If the tall unit has another back panel in addition to
the element back panels, this must be removed.
¡ Only fit the appliance up to a height which allows
accessories to be easily removed.
22.6 Installing two appliances on top of
each other
Your appliance can also be installed above or below
another appliance. Observe the installation dimensions
and the installation instructions when installing appli-
ances on top of each other.
¡ To ventilate the appliances, the intermediate floor
must have a ventilation cut-out.
¡ To ensure sufficient ventilation of the two appli-
ances, there must be a ventilation opening of at
least 200 cm² in the base area. To do this, trim the
base panel or fit a ventilation grille.
a raised in mm
42
52
32
32
a flush in mm
43
53
43
35
¡ Ensure that air exchange is guaranteed in accord-
ance with the diagram.
¡ Only fit appliances up to a height that allows ac-
cessories to be easily removed.
22.7 Corner installation
Observe the installation dimensions and the installation
instructions when installing in a corner.
¡ To ensure that the appliance door can be opened,
you must take the minimum dimensions into consid-
eration when installing in a corner. The dimension
is dependent on the thickness of the unit front and
the handle.
22.8 Electrical connection
In order to safely connect the appliance to the elec-
trical system, follow these instructions.
¡ The appliance corresponds to protection class I and
must only be operated with a protective earth con-
nection.
¡ The fuse protection must correspond to the power
rating specified on the appliance's rating plate and
to local regulations.
¡ The appliance must be disconnected from the
power supply whenever installation work is being
carried out.
¡ The appliance must only be connected using the
power cable provided.
Installation instructions en
b in mm
5
5
5
2
29