4.3

Control Module

El módulo electrónico consta de dos módulos, uno de display, y otro,
de potencia.
The function of the display module are:
Display the spin speed, the temperature, the rest time and the
start time preselection
Include the option buttons and the start/pause button.
The function of the control and power module are:
drive all the elements, with one relais the heating element and
with triacs the other elements (motor, valves and drain-pump).
evaluate the incoming signals of the NTC, tachogenerator and
pressure switch and
control of the programe.
The main characteristic is that the variant coding is made through the
programe selector and the buttons.
That means that all the modules are able to be coded.
The frecuency window of the module is: 45...76 Hz
Electrostatic sensitive devices!
Please observe handling regulations.
209_58300000115677_ara_en_f.doc – 26.03.08
4.4

Door lock

The door lock is electromechanic, and it consist in a PTC, which is
heated when it receives tension and the inside wax is expanded and
blocks the door.
At the end of the wash, it is necessary to wait for a time before
opening the door
There are three cases in which the door keeps blocked:
It receives signal of movement fo the drum from the
tachogenerator.
If there is water level N1.
If the temperature is higher than 60º
Seite 11 von 34