Siemens SITRANS RD500 Manuel d'utilisation

Configuring Reports

The RD500 provides reports which are HTML files sent via email or FTP . The report page
includes the current overview page information, and the current IP address information.
The Enable property activates the report feature.
The Sync Period property determines how often the report is sent.
The Sync Delay indicates how many minutes after the hour the report will be sent.
The Format property indicates the type of file format for the report.
Method property indicates whether the report will be sent via Email or FTP or both.
Send Logs property determines whether to include the last datalog or event log with
the report.
Send Now sends the report immediately.
Page 36
SITRANS RD500 – OPERATING INSTRUCTIONS
7ML19985MA01