Ricoh Provence-P2W Manuel d'entretien - Page 33
Parcourez en ligne ou téléchargez le pdf Manuel d'entretien pour {nom_de_la_catégorie} Ricoh Provence-P2W. Ricoh Provence-P2W 48 pages. Machine code: j006
15 July 2005
6.5.2 CONTROL BOARD
J001/J003 Manual Reference
Comment
XTL
PC
CARD
Cartridge Connect
Board
ID Chip
PC
Sub Scan
Main Scan
COM Board
K
C M Y
DRV Board I/F
6.8.2 Control Board
The J006 has a new control board.
CPU
CPU Bus
SSCG
SDRAM
XTL
USB
CTL
FLASH
ROM
I2C
Controller
Local Bus
NVRAM
Debug
Serial I/F
Vertical Motor
Horizontal Motor
Image Data (CMYK)
Drive
Wave
Drive
Drive
Wave
Wave
O
P
G=34
ASIC:TOTTI2
Analog Board
Reset Circuit
+5V→+5VE1/+5VE2/+3.3V/+2.5V/+1.5
25
DETAILS
5V Current Limit Release
37V Power ON
Operation Panel Button LEDs
Ink End LED
Air Release SOL Drive
Feed CL
Maintenance Motor Control
Ink Supply Motor 1 CK Control
Ink Supply Motor 2 MY Control
Tray 2 CL Control
Tray 2 Motor Control
PP High Voltage Control
Remote Power ON
Cartridge Cover SN
Operation Panel Switch
Sub Tank Ink Supply SN
Bypass Set SN
Envelope Position SN
Power Pack Leak SN
Trailing Edge SN
Tray 2 Set SN
Horizontal Encoder
Vertical Encoder
Duplex Unit Set SN
Duplex Unit Cover Open SN
Maint. Mechanism Cam SN
Ink Waste Tank Full SN
Transport Roller Temp. SN
Cover Open SN
Sub Tank Full SN
Registration SN
Print Head Temperature SN
Tray 1 Humidity SN
Power Circuit
Device
External Device Signal
P2W-6-21.WMF