Set Temperature and Time
The temperature and time are set at the factory, but you can change the settings
according to how you use the finisher.
To set the temperature and time, press the [Temperature] key or the [Fixing Time]
key.
•
You can select either "Low" or "High" for the temperature.
•
You can select "Short", "Medium", or "Long" for the time.
It is set to a fixed number for each.
You can set any number. Press the [Temperature] key or the [Fixing Time] key for
2 seconds or more, and use the [Temperature] key or the [Fixing Time] key to
set the temperature and time. To confirm the settings, press the [Preheat] key. To
cancel the settings, press the [Stop/Unlock] key.
•
You can set the temperature in units of 5°C (41°F) between 140°C (284°F)
and 180°C (356°F).
•
You can set the time in units of 30 seconds between 30 seconds and 6 min-
utes.
12