Source DC service
requirement
Environmental conditions
Temperature
Humidity
Altitude
Heat dissipation
Acoustic noise
Shock
Vibration
4
grms is root mean square value of acceleration; gpk is peak acceleration
All contents are Copyright © 1992–2006 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information.
60A
60A
Operating: 32 to
Operating: 32 to
104°F (0 to 40°C)
104°F (0 to 40°C)
Nonoperating: -4 to
Nonoperating: -4 to
149°F (-20 to 65°C)
149°F (-20 to 65°C)
Operating: 10–90%
Operating: 10–90%
noncondensing
noncondensing
Nonoperating: 5–95%
Nonoperating: 5–95%
noncondensing
noncondensing
Operating: 0–10,000
Operating: 0–10,000
ft. (0–3000m)
ft. (0–3000m)
Nonoperating: 0–
Nonoperating: 0–
15,000 ft. (0–4570m)
15,000 ft. (0–4570m)
DC (max): 4212 VA
DC (max): 2430 VA
@ 14372 Btu/hr
@ 8291 Btu/hr
AC (max):4651 VA @
AC (max):2790 VA @
15870 Btu/hr
9519 Btu/hr
70 dBa maximum
70 dBa maximum
Operating (halfsine):
Operating (halfsine):
21 in./sec (0.53m/sec)
21 in./sec (0.53m/sec)
Nonoperating
Nonoperating
(trapezoidal pulse):
(trapezoidal pulse):
20g, 52 in./sec (1.32
20g, 52 in./sec (1.32
m/sec)
m/sec)
4
Operating: 0.35 grms
Operating: 0.35 grms
from 3 to 500 Hz
from 3 to 500 Hz
Nonoperating: 1.0
Nonoperating: 1.0
grms from 3 to
grms from 3 to
500 Hz
500 Hz
60A
60A
Operating: 32 to
Operating: 32 to
104°F (0 to 40°C)
104°F (0 to 40°C)
Nonoperating: -4 to
Nonoperating: -40 to
149°F (-20 to 65°C)
158°F (-40 to 70°C)
Operating: 10–90%
Operating: 5–90%
noncondensing
noncondensing
Nonoperating: 5–95%
Nonoperating: 5–95%
noncondensing
noncondensing
Operating: 0–10,000
Operating: 0–14,000
ft. (0–3000m)
ft. (0–4267m)
Nonoperating: 0–
Nonoperating: 0–
15,000 ft. (0–4570m)
16,000 ft. (0–4877m)
DC (max): 1630 VA @
DC (max): 1280 VA
5562 Btu/hr
@ 4367 Btu/hr
low line AC (max):
AC (max): 1341 VA
1708 VA @ 5828
@ 4575 Btu/hr
Btu/hr
high line AC (max):
1950 VA @ 6654
Btu/hr
70 dBa maximum
70 dBa maximum
Operating (halfsine):
Operating (halfsine):
21 in./sec (0.53m/sec)
5g (11 m/sec)
Nonoperating
Nonoperating
(trapezoidal pulse):
(trapezoidal pulse):
20g, 52 in./sec (1.32
15g (11 m/sec)
m/sec)
Operating: 0.35 grms
Operating (sinusoidal):
from 3 to 500 Hz
3–500 Hz @ 0.15 gpk
(random): 2.5–200 Hz
Nonoperating: 1.0
@ 0.33 grms
grms from 3 to
500 Hz
Storage (sinusoidal):
10–500 Hz @ 0.8 gpk
(random): 2.5–200 Hz
@ 1.05 grms
Page 4 of 9