LADDER PROGRAMMING: ELEMENTS & FUNCTION BLOCKS
In ladder programming, the ladder elements and functional blocks are connected to create the logic needed for any application. The following section gives the
description of each element that is used in SPR-soft III ladder programming.
INPUTS
The Series 900 relay provides two types of inputs: digital and analog
AC Model: Digital Inputs (1 - 8)
DC Model: Digital Inputs (1 - 6), Analog Inputs (V1, V2)
I1, I2, ..... I8
J1, J2, ..... J8
K1, K2, ..... K8
L1, L2, ..... L8
i1, i2, ..... i8
j1, j2, ..... j8
k1, k2, ..... k8
l1, l2, ..... l8
TIMERS
The Series 900 relay provides 16 timers which can be configured as:
i. ON Delay, ii. OFF Delay, iii. Single Shot, iv. Cyclic ON/OFF, v. Cyclic OFF/ON,
vi. Make Interval, vii. Break Interval, viii. Delayed Make Interval, ix. Make/Break
Interval OFF/ON, x. Make/Break Interval ON/OFF
T1, T2, ..... T16
t1, t2, ..... t16
Timer Mode
D
Reset Input
Preset Time Unit
S
S
Current Time Unit
ANALOG COMPARATORS
The Series 900 relay provides 12 analog comparators which can be used for
comparison between values of two analog signals or between an analog
signal and any absolute value.
A1, A2, ..... A12
a1, a2, ..... a12
Compare Input
V1
Compare Function
ABS
Absolute Value
COUNTERS
The Series 900 relay provides 16 counters which can be configured as:
i. Up Counter, ii. Down Counter
C1, C2, ..... C16
c1, c2, ..... c16
Preset Value
Direction Input
Counter Unit
Reset Unit
SOFT TEXT MESSAGES
The Series 900 relay provides 16 soft text message blocks which can be used
to display text messages, the preset value and current value of any special
function block or the current date and time.
X1, X2, ..... X16
Used for viewing Alarms, HMI Functionality
LIFETIME WARRANTY
GUARANTEED SAME-DAY SHIPPING
ADVANTAGE PRICING
Base Module
Normally
Expansion Module 1
Open (NO)
Expansion Module 2
Contact
Expansion Module 2
Base Module
Normally
Closed
Expansion Module 1
(NC)
Expansion Module 2
Contact
Expansion Module 2
Timer Coil/Normally Open (NO) Contact
Normally Closed (NC) Contact
Trigger Input
Timer Number
Make/Break Status of 'NO'
TRG
T1
Locked/Unlocked State
RES
X
000.0
OF
Preset Time Unit
006.0
OF
Current Time Unit
Normally Open (NO) Contact
Normally Closed (NC) Contact
ANALOG
0000
P1
Analog Comparator No
>
X
1023
Locked/Unlocked State
Make/Break Status of 'NO' Contact
Counter Coil/Normally Open (NO) Contact
Normally Closed (NC) Contact
00004
00000
Current Value
DIR
RET
Retentive Selection (Y/N)
C1 N
CNT
Locked/Unlocked State
X
RES
Make/Break Status
of 'NO' Contact
Counter Number
OUTPUTS
The Series 900 relay provides digital outputs: Base Module (4), Expansion
Module (4). The outputs can be configured as:
i. State Change (Contactor), ii. Level Change (Remote Control), iii. Bi-stable (Set
Reset)
Q1, Q2, ..... Q4
Normally
U1, U2, ..... U4
Open (NO)
V1, V2, ..... V4
Contact
W1, W2, ..... W4
q1, q2, ..... q4
Normally
u1, u2, ..... u4
v1, v2, ..... v4
Contact
w1, w2, ..... w4
TIME SWITCHES
The Series 900 relay provides 16 time switches which can be used for daily or
weekly applications.
1,
2, ..... 16
1,
2, ..... 16
Current Time
Start Time
ON
OFF
End Time
COMPARE COUNTERS
The Series 900 relay provides 16 compare counters which can be used for
comparison between values of two counters or between a counter and any
absolute value.
i. Up Counter, ii. Down Counter
P1, P2, ..... P16
p1, p2, ..... p16
Compare Input
C1
Compare Function
ABS
Absolute Value
AUXILIARY RELAYS
The Series 900 relay provides 64 auxiliary relays which can be used to expand
a rung from one line to another line. It can be configured as:
i. State Change (Contactor), ii. Level Change (Remote Control), iii. Bi-Stable (Set
Reset)
M1, M2, ..... M64
Auxiliary Coil/Normally Open (NO) Contact
m1, m2, ..... m64
Z-KEYS
Z-Keys are soft keys located on the front of the device. They behave exactly
like the physical inputs (discrete inputs). The only difference is that they do
not correspond to smart relay connection terminals, but to the four gray
buttons on the front panel.
Z1, Z2, ..... Z4
z1, z2, ..... z4
Z-Keys can be used as navigation keys for current displayed menu.
To access the Z-Keys while the program is running, press the ALT key,
then press Z1 - Z4.
Base Module
Expansion Module 1
Expansion Module 2
Expansion Module 2
Base Module
Closed
Expansion Module 1
(NC)
Expansion Module 2
Expansion Module 2
Normally Open (NO) Contact
Normally Closed (NC) Contact
From
To
Time Switch No
MO SU
08 : 11
1
Make/Break Status
X
of 'NO' Contact
09 : 15
12 : 00
Locked/Unlocked State
Normally Open (NO) Contact
Normally Closed (NC) Contact
COMPARE
00000
P1
Analog Comparator No
>
X
01023
Locked/Unlocked State
Make/Break Status of 'NO' Contact
Normally Closed (NC) Contact
Normally Open (NO) Contact
Normally Closed (NC) Contact