Replacing Assembly Units
3.7

Replacing the PCB Control

Fig. 13
Replacing PCB Control
 Loosen four screws (1).
 Pull-out all cables from the connectors of the PCB Control (2).
 Pull the PCB Control out of the housing.
 Mount the new PCB in the opposite order.
3
4
Fig. 14
PCB Control - connectors
Pos. Connector
3
Periphery
4
LP Sensor Centering gear side
5
LP Sensors Reference+Diameter
6
LP Spring Contact
7
LP Sensor Touchguard
8
Service Button
9
Sensor Applicator Locked
10
Ventilator
11
Motor Touchguard
12
LP Sensor Centering winder side
13
Motor Winding
Table 1
PCB Control - connectors