Argent Data Systems ADS-SR1 Manuel de l'utilisateur - Page 11
Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Argent Data Systems ADS-SR1. Argent Data Systems ADS-SR1 20 pages. Simplex repeater
General Options
##71 – Repeater On
Turns on the simplex repeater function. The unit will automatically repeat
transmissions. The repeater is turned on by default.
##70 – Repeater Off
Turns off the simplex repeater function. The unit will respond to
commands, record 'say again' messages, play announcements, and accept
voicemail as usual, but it won't automatically repeat transmissions.
##14<1/0> – Say-Again Mode On/Off
Enables or disables 'say again' mode. Pressing '0' will cause the repeater
to retransmit the last transmission heard when this mode is enabled. Default is
on.
Example: ##141 – Enable 'say again' mode.
##06<time> – Set Auto-Off Timer
The repeater function automatically shuts off after the specified idle
interval, and may be turned on again with '3' or off with '6'. These on and off
functions do not require the access code to be entered. Setting the auto-off timer
to 0 disables this function. Default is disabled.
Example: ##06045 – Set timer to 45 seconds
##19<nn> - Set Minimum Transmission Time
This setting specifies, in tenths of a second, how long a transmission must
be before it will be repeated. This can be used to avoid 'kerchunking' of the
repeater. When using the repeater to check for missed calls with the 'say again'
feature, setting this number higher will prevent short transmissions from
overwriting the 'say again' memory. Default is 0.2 seconds.
Example: ##1904 – Set minimum transmission time to 0.4 seconds
##17<time> - Repeater Timeout
Sets the maximum transmission length allowed. If an incoming
transmission exceeds this length, the repeater will stop recording and start re-
transmitting it immediately. Set to zero to disable. Default is disabled.
Example: ##17045 – Set repeater timeout to 45 seconds
10