1. Verify all components included with the extender set are present
before installation.
2. If the extenders are going to be permanently mounted to a surface,
attach the included mounting brackets with the supplied screws.
3. Turn off power and disconnect the audio/video equipment by
following the manufacturer's instructions.
4. Connect Category 6 or greater twisted pair cable with RJ45 connectors
between the transmitter (DL-HDE100-TX) and the receiver (DL-HDE100-
RX). TIA/EIA-568B straight-through wiring connections must be used
with all HDBaseT extenders.
5. Connect an HDMI cable and any desired control accessories between
the display and the receiver (DIGI-HDE100-RX).
6. Connect an HDMI cable and any desired control accessories between
the source and the transmitter (DIGI-HDE100-TX).
7. Connect the included power supply to the transmitter or receiver and
lock the power supply to the power connector by twisting the locking
collar counter clockwise.
8. Power on attached audio/video devices.
Passing IR Signals:
The DL-HDE100 is capable of passing IR signals between 33 and 55 KHz. To prevent damage to
any of the electronics, the extenders should be powered off while inserting or removing any IR
components. Inserting an IR transmitter into the IR IN port may damage the IR circuit for that
extender.
IR OUT: The IR transmitter (IR emitter) must be plugged into the IR OUT port.
IR IN: The IR receiver (IR eye) must be plugged into the IR IN port.
Important notice:
Do not attempt to disassemble or alter the extender housing. There are no user-
serviceable parts inside the unit. Doing so will void your warranty.
To minimize the possibility of equipment damage from electrostatic discharge
(ESD), all source and destination equipment must be powered off during installation.
Do not connect the extender to a telecommunication outlet wired to unrelated
equipment. Doing so may damage the unit or any connected equipment. Ensure all
connected twisted pair cabling is straight-through (point-to-point).
Allow proper ventilation to reduce the risk of thermal failure.
Instructions