SpeakerTrack 60 Camera
Factory resetting the cameras
Lift the cameras from the carrier tray in order to reset them.
The pinhole button is on the back panel of the camera.
A factory reset should only be performed by a system adminis-
trator or in contact with Cisco technical support.
The cameras will be reset to factory defaults, and all configura-
tion and logs will be erased.
It is not possible to undo a factory reset.
To perform a factory reset:
1. Remove the top cover of the SpeakerTrack 60 device.
2. Unscrew the wing nut that fastens the camera.
3. Locate the pinhole button at the back of the camera.
See also
thePrecision60 Camera
4. Use a pen or similar to press and hold the factory reset
button for 10 seconds.
5. The camera LED will be lit red during the factory reset.
Do not unplug power.
6. When the factory reset is complete, the camera restarts
and the camera LED lights up.
7. Set the camera back to the tray and tighten the wing nut
(see picture 2 on the right).
8. Repeat steps 2-7 with the other camera.
9. Set back the top cover.
D15296.10 Cisco Quad Camera, Precision 60, SpeakerTrack 60, and PTZ-12 Camera SEPTEMBER 2019.
Introduction
Physical interface
chapter.
Connecting to a codec
1
2
3
33
Factory reset
Factory reset
Appendix
When replacing the camera,
make sure the pins on the base
plate fit the holes in the camera
interface plate.
Locate the pinhole on the back
panel of the camera.
Copyright © 2019 Cisco Systems, Inc. All rights reserved.
Camera guide