Sony BVP-E30 series Manuel - Page 18

Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Sony BVP-E30 series. Sony BVP-E30 series 34 pages. Sdtv portable cameras
Également pour Sony BVP-E30 series : Manuel d'utilisation (36 pages), Brochure & Specs (14 pages), Manuel d'utilisation (38 pages)

Sony BVP-E30 series Manuel

3-2. Connection Setting on MSU-900/950

Enter the Engineer Mode for setting.
For details of the menu operation block, menu operation method and setting method in Engineer Mode, refer to the Opera-
tion Manual.
3-2-1. Network Confi guration Menu
Menu display method
1. Press the menu operation block [CONFIG] button to display the Confi guration menu.
2. Touch the Confi guration menu [MSU] button to display the MSU Confi guration menu.
3. Touch the MSU Confi guration menu [Network] button.
Network Configuration
Engineer Mode
CNS
Ethernet IF
TCP/IP

3-2-2. Camera Network System Setting Menu

Camera Network System Setting
Engineer Mode
Legacy
Mode:Active
Bridge
Target:192.168.0.100
Mode:Master
MCS
Master:192.168.0.101
MSU No.
1
3-2 (E)
Exit
Exit
Set
Mode
Cancel
Set
Mode
Set
Item
Function
CNS
Display of the setting menu such as the Camera
Network System (CNS) connection mode
Ethernet IF
Display of the LAN connection setting menu
TCP/IP
Display of the setting menu related to TCP/IP
such as IP address
Item
Function
Legacy
Connection using the conventional CCA cable
Bridge
One-to-one connection mode
Mode Set
Sub mode of the Bridge mode
Move to the Bridge mode Set menu
MCS
Multiple unit connection mode
Mode Set
Sub mode of the MCS mode
Move to the MCS mode Set menu
MSU No.
MSU equipment number setting
n
In the MCS mode, set the numbers so that they
should not duplicate among the multiple units of
MSU within the same system.
Camera Network System