Sony XC-ST50 Manuel technique - Page 11
Parcourez en ligne ou téléchargez le pdf Manuel technique pour {nom_de_la_catégorie} Sony XC-ST50. Sony XC-ST50 30 pages. Black-and-white video camera module
Également pour Sony XC-ST50 : Spécifications (4 pages), Manuel de l'utilisateur (31 pages), Manuel du produit (2 pages), Manuel technique (31 pages), Manuel (4 pages)
Sample input timing chart 2
Continuous signal: 15.734 kHz (XC-ST51/ST50/ST30) Allowable frequency value ±1%,
EXT HD
EXT VD
VD interval (T): 262.5 H or more (XC-ST51/ST50/ST30) and less than 1 second (Recommended),
Four or more VD pulses are required.
Exposure time for the Odd field
Exposure time for the Even field
Frame Accumulation (Factory setting)
Video output
Odd and even fields are determined by the phase of the EXT HD/VD signal input from the outside.
Frame image output with a strobe light
The factory setting for this camera is Frame
Accumulation. The images obtained when the normal
continuous shutter or trigger shutter is used are field
images (vertical resolution: 243 lines).
Using a strobe light and Restart/Reset mode, you can
obtain bright frame images by synchronizing any
strobe light. (Vertical resolution: 485 lines).
Sample input timing chart
EXT HD
Continuous signal: 15.734 kHz (XC-ST51/ST50/ST30) Allowable frequency value ±1%,
EXT VD
VD: 1/60 sec (XC-ST51/ST50/ST30), 1/50 sec (XC-ST51CE/ST50CE/ST30CE)
Four or more VD pulses are required.
Strobe light
Exposure time for the Odd field
Exposure time for the Even field
Frame Accumulation (Factory setting)
Video output
Odd and even fields are determined by the phase of the EXT HD/VD signal input from the outside.
Avoid lighting the scene during the light-emitting inhibit zone defined below. (The field is transfered to the
storage area of the CCD, so it can be read out.)
Note
For best performance, it is recommended that you not flash between VD and VD + 10 H (XC-ST51/
ST50/ST30)/16 H (XC-ST51CE/ST50CE/ST30CE).
XC-ST51/ST51CE
XC-ST50/ST50CE
XC-ST30/ST30CE
15.625 kHz (XC-ST51CE/ST50CE/ST30CE) Allowable frequency value ±1%
312.5 H or more (XC-ST51CE/ST50CE/ST30CE) and less than 1 second (Recommended)
Invalid image
15.625 kHz (XC-ST51CE/ST50CE/ST30CE) Allowable frequency value ±1%
Invalid image
T
1/60
1/60
second
second
Odd
Even image
image
Valid frame image
Odd
Even
image
image
Valid frame image
Mode Settings