Sony XCD-SX90CR Manuel d'entretien - Page 18
Parcourez en ligne ou téléchargez le pdf Manuel d'entretien pour {nom_de_la_catégorie} Sony XCD-SX90CR. Sony XCD-SX90CR 30 pages. Digital camera module
Également pour Sony XCD-SX90CR : Manuel (4 pages), Manuel technique (38 pages), Manuel technique (39 pages), Mode d'emploi (2 pages)
2-2-2. Color Camera
(XCD-U100CR/SX90CR/V60CR)
1. Shoot the pattern box in the center of the window
through the clear chart at the wide end.
2. Start the IIDC_CAM**** software.
3. Click WFM (Waveform Monitor) in the menu.
The waveform is displayed.
WFM
4. Start the IIDC_CAM**** software.
The IIDC control window is displayed.
5. Set the lens iris to F1.4. (Zoom at the Tele end)
6. Click the Exposure tab and adjust the shutter in the
window so that the Green level reaches close to 100%
(does not exceed 100% (236)) in the WFM window.
The shutter value (reference value) at which the Green
level reaches close to 100% on WFM is as follows.
XCD-V60CR:
28
XCD-SX90CR: 41
XCD-U100CR: 36
Exposure tab
2-4
xxxxxxxx
xxxxxxxx
xx
7. Click the "Adjust" tab in the IIDC control window.
[AdjustWB] button
[Gain0dB] button
8. Click the [AdjustWB] button to adjust the color.
9. Click the [Gain0dB] button.
The Gain 0dB adjustment is performed.
10. Check that the adjustment level satisfies the specifica-
tion A.
A = 235 1 step
n
If the specification A is not satisfied, perform the
procedure from step 1 again.
11. After the adjustment is completed, click the [Write]
button and write the adjustment value.
12. Click the [AdjustWB] button.
The WB adjustment is performed.
13. Check that the adjustment level satisfies the specifica-
tion B.
B = 235 1 step
n
If the specification B is not satisfied, perform the
procedure from step 1 again.
14. After the adjustment is completed, click the [Write]
button and write the adjustment value.
Green level
[Write] button
xxxxxxxx
xxxxxxxx
xx
XCD-U100/SX90/V60
XCD-U100CR/SX90CR/V60CR