Sony XCU-CG160 Manuel technique - Page 21

Parcourez en ligne ou téléchargez le pdf Manuel technique pour {nom_de_la_catégorie} Sony XCU-CG160. Sony XCU-CG160 45 pages. Digital video camera module

Sony XCU-CG160 Manuel technique

Frame Rate

Auto frame rate

The read cycle is set to allow the frame rate to be the maximum value automatically, according to the current shutter
setting and the partial scan setting in free-run operation (shutter has priority). The next exposure is performed during
image output, and the next image output is started immediately after finishing all image output. The frame rate is
reduced by setting a shutter time longer than the image output time.
Feature
AcquisitionFrameRateAuto False (0)

Specifying the frame rate

The frame rate of the image output can be specified in free-run operation. Enter the value of the frame rate [fps]. A frame
rate faster than the fastest frame rate cannot be set.
Feature
AcquisitionFrameRate
0.0625 to 100 to 4000
* The upper limit varies depending on the partial scan setting.

Displaying the frame rate

The current frame rate during auto frame rate operation is displayed.
Feature
AcquisitionFrameRateActual

Fastest frame rate for partial scanning

The fastest frame rate varies depending on the Height parameter for partial scanning.
2000
1800
1600
1400
1200
1000
800
600
400
200
0
0
Parameter
Setting
Auto frame rate off
True (1)
Auto frame rate on
Parameter
*
Frame rate [fps]
200
400
Setting
XCU-CG160 Normal Mode:Mono12p, Mono8
XCU-CG160C Normal Mode:Mono8, BayerRG12p, BayerRG8
XCU-CG160C Normal Mode:YCbCr422_8
XCU-CG160C Normal Mode:BGR8,YCbCr8
XCU-CG160 Fast Mode:Mono8
XCU-CG160C Fast Mode:BayerRG8
XCU-CG160C Fast Mode:Mono8, BGR8
600
21
800
1000