How to Use Table 1-1.:
Use table 1-1. by converting hexadecimal number of each digit
into decimal number (see table 1-2). If an error occurred by two
or more causes, respective numbers are added.
Table 1-2. Hexadecimal number - Decimal number Conversi
Hexadecimal
Decimal
0
0000
1
0001
2
0010
3
0011
4
0100
5
0101
6
0110
7
0111
Example 1: If "42" is displayed
Higher bit: 4=0100 → b6
Lower bit: 2=0010 → b1
This case shows that retry was made due to combined causes of
"CLV unlock" and "ADIP error ".
Example 2: If "A2" is displayed
Higher bit: A=1010 → b7 + b5
Lower bit: 2=0010 → b1
This case shows that retry was made due to combined causes of
"cannot access", "IV-R", and "ADIP error ".
Note: Some sets may display "MD ERR TOC" depending on the
contents of CD disc to be recorded.
In this case, retry aging using another CD disc.
Hexadecimal
Decimal
8
1000
9
1001
A
1010
B
1011
C
1100
D
1101
E
1110
F
1111
Table 1-3. Error Messages
Error Message
1
MD ERR NO DISC
2
MD ERR A-ERASE
3
MD ERR R-PAUSE
4
MD ERR D-INPUT
5
MD ERR PLAY
6
MD ERR TOC
7
CD ERR FOCUS
8
CD ERR GFS
9
CD ERR TOC
10
CD ERR SEARCH
11
CD ERR TRY1 SW
12
CD ERR TRY2 SW
13
CD ERR TRY3 SW
14
CD ERR CARRIER
15
CD ERR GEAR
16
CD ERR CHUCK
17
CD ERR TRY IN
18
CD ERR TRY OUT
19
CD ERR ServoOK
– 3 –
Description
TOC of MD cannot be read (disc
error, etc.)
MD all erasing failed
(premaster, protect, or disc
error)
Pause of MD recording failed
MD digital input is not locked
Last music of MD cannot be
played (access error)
TOC content of MD is erroneous
(total tracks are wrong)
CD focusing failed
CD GFS failed
16 seconds elapsed after TOC of
CD was read
16 seconds elapsed after CD was
searched
Switch in CD tray 1 is faulty
Switch in CD tray 2 is faulty
Switch in CD tray 3 is faulty
Carrier operation did not com-
plete within the specified time
Gear operation did not complete
within the specified time
Chucking did not complete
within the specified time
Tray was not closed within the
specified time
Tray was not opened within the
specified time
This massage is displayed when
the aging is tried through CD
aging is disabled due to other