Également pour ACU-RITE 745604-NN : Mise à jour du logiciel (6 pages), Mise à jour du logiciel (5 pages), Mise à jour du logiciel (6 pages), Mise à jour du logiciel (6 pages), Mise à jour du logiciel (5 pages), Mise à jour du logiciel (6 pages), Mise à jour du logiciel (6 pages), Mise à jour du logiciel (7 pages), Mise à jour du logiciel (3 pages), Mise à jour du logiciel (5 pages), Mise à jour du logiciel (3 pages)

ACU-RITE 745604-NN Mise à jour du logiciel
These enhancements/changes were made:
Corrected the following errors related to stepover and Z pass calculations: 1. Tool Stepover field
correctly handles conversion between percentage or distance (inch/mm). If the step has no
programmed tool, the conversion is correctly applied to the current tool. 2. Z Peck/Pass fields
correctly handle display and entry after switching between number or distance (inch/mm).
To prevent circular referencing, soft keys for selecting internal references (i.e. X1, X2, X) are
disabled if the selection is invalid.
Corrected an issue in which the software could terminate unexpectedly when attempting to run
a G-Code program directly from a non-existing drive (i.e. USB or network share).
If the keyboard dialog is opened from the engrave text field, pressing the USE key closes the
keyboard dialog instead of closing the stepform dialog.
Corrected an issue in which the View Setup dialog was not functional after opening the Block
Form dialog and pressing CANCEL.
Corrected the following issues related to feedrate conversions 1. Feedrate values in programs
are correctly converted between in/min and mm/min to match the Job Setup selection. 2.
Feedrate values are correctly converted from feedrate units to program units in the custom
pocket sub-cycle and radial pocket cycles.
Running of the radial slot step has been modified to allow for a slot width equal to the tool
diameter.
The simulation graphics now rerun after the scaling setting has been changed, in order to
correctly reflect the new output.
Corrected an issue when manually starting a simulation run (i.e. Decimal key), the blockform
and/or contour layer were not re-evaluated and thus could be incorrect in some rare cases.
The AutoService filename has been changed from nc_autosave_service#.zip to
nc_auto_service#.zip which allows the complete file name to show in Program Functions.
If any issues are encountered, please contact your service representative for assistance or
contact technical support at
if you have any questions.