Argo-Hytos RPE3-062 S3 Series Manuel d'utilisation - Page 10

Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} Argo-Hytos RPE3-062 S3 Series. Argo-Hytos RPE3-062 S3 Series 16 pages. 4/2 hydraulic directional control valve with axial spool position sensor, solenoid operated, suitable for use as a safety component with certified functional safety

Argo-Hytos RPE3-062 S3 Series Manuel d'utilisation
Solenoid coil connector type,
E1, E2
E3A, E4A
Ingress protection IP65
Ingress protection IP67
52 (2.05)
The indicated IP protection level is only achieved if the connector is properly mounted.
The possible and preferred combinations of connector type and control voltage are listed in the HC 8007 Product Catalog:
Coils for valve control solenoids
Manual Override ,
dimensions in mm (in)
Designation N1
- cap nut covered
Plastic nut
3+1 Nm
(2.2+0.7 lbf.ft)
a
79,5 (3.13)
5. Target user group
All of the above activities related to this valve, in particular installation and connection to the hydraulic circuit, require specialist technical knowledge
and experience in the field of hydraulics. The minimum level of competence required is CETOP level 2. This level is generally defined as performing a
variety of activities that require an understanding of technical factors and contexts. This may lead to the need for correct interpretation (e.g.
tolerances, operating methods) or the application of various non-repetitive procedures. This may require the performance of checks, simple analysis
and diagnostics, and the ability to react to changes in an operational manner. Teamwork is often necessary.
The connection of solenoid coils to the supply voltage must only be carried out by persons with the appropriate electrical qualifications.
All operations must be carried out with responsibility for correctness and quality, as this is a dangerous area of product use.
Elektrické připojení elektromagnetu a snímače polohy smí provádět jen osoba s odpovídající elektrotechnickou kvalifikací.
› minors (the exception is practical training of pupils under the professional supervision of a teacher)
› without established professional competence
› under the influence of alcohol and/or drugs
› patients whose medical condition could affect safety (reduced attention and ability to react in time, excessive fatigue)
› under the influence of drugs that have a demonstrable effect on attention and timeliness
› allergic to hydraulic working fluids
6. Operating instructions broken down into product life stages
6.1 Transportation and storage of the product
The valve is packaged in vacuum shrink-wrapped PE film and protected against moisture and dust as standard.
An identification label is affixed to the packaging.
The products should only be stored for the necessary time at a temperature of 0 to +30 °C in a dry place with a relative humidity of up to 65 %.
After extended periods of storage, we recommend checking the product for corrosion damage, replacing seal at the base of the body and flushing
the product with clean oil before connecting it to the hydraulic circuit.

6.2 Product installation.

6.2.1 Product installation
› Check that the valve type on the identification plate is correct.
› Cut the packaging with scissors and carefully remove the valve from the packaging.
› Unpack the valve in a clean place and prevent contamination of the valve.
› The packaging is made of PE and can be easily contaminated with residual hydraulic oil from the valve.
Dispose of the packaging in accordance with the applicable environmental regulations.
› Just before mounting the valve, remove the plastic shipping plate from the connection pattern on the lower base of the body, check the four
sealing rings for completeness and integrity and the connection pattern for cleanliness. Replace damaged rings with new ones (see spare parts).
Return the undamaged shipping plate to the manufacturer.
Page 10
dimensions in mm (in)
E5
Ingress protection IP65
In the event of solenoid coil failure or power failure, the spool of the valve can be repositioned,
e.g. in order to reach a safe position of the device, by means of a manual override.
By unscrewing the plastic nut securing the coil, you gain access to the stopper with the emergency control
pin at the end of the control system.
The pin can be moved manually together with the armature and spool using a pin up to 3.3 mm diameter.
However, the valve can only be operated manually up to a pressure of 20-25 bar in the T-channel.
E8, E9
E12A, E13A
Ingress protection IP67 / IP69K
NOTE:
A = standard 300 mm(11.8 in),
another lengths on request
Operating_Instructions_RPE3-062x/xS3_14087_1en_05/2022
www.argo-hytos.com