ACU-RITE SENC 150 Manuel d'installation - Page 3
Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} ACU-RITE SENC 150. ACU-RITE SENC 150 4 pages. Chevalier fsg-2a 1224 surface grinder cross feed “x” axis
Également pour ACU-RITE SENC 150 : Manuel d'installation (8 pages), Manuel de référence (20 pages), Manuel d'installation (6 pages), Manuel d'instructions (12 pages)
SENC 150
Encoder installation ...
•
Insert the encoder into the spar as shown.
•
Center the encoder in the spar from end to end.
•
Lock in place by tightening the M4 set screws.
Attaching the reading head ...
*8-32 x 5/8" SHCS (2)
Reading head
bracket and spacer
•
With the carriage at the center of travel, attach the
bracket to the reading head.
•
Transfer punch the two mounting hole locations to
the base using the spacer as a guide.
•
Remove the bracket, drill and tap the locations for
1/4-20 x 1/2" deep.
P.N. 385076.130 Ed B 2/06
M4 x 8mm SHSS (3)
Transfer punch hole locations (2)
Drill and tap for 1/4-20 x 1/2" deep
Installation Manual 385076-000
Encoder Installation Manual For: Chevalier FSG-2A 1224
Surface Grinder: Cross Feed "X" Axis
Gap: .03" - .18"
Spacer
Reading head bracket
•
Attach the bracket with the spacer to the base.
•
A gap of .03" - .18" will exist between the reading
head and the bracket.
•
Adjust the bracket so that the head mounting holes
align with the bracket and secure in place.
Reading head
leveling set screws (3)
•
Insert the *8-32 x 5/8" SHCS, but do not tighten.
•
There will be a gap of .03" - .18" between the
bracket and the reading head.
•
Insert and set each leveling screw by placing a .001"
- .003" feeler gage between the set screw and the
bracket.
•
Adjust each set screw until a slight drag is felt on
the feeler gage.
•
Evenly tighten the two 8-32 SHCS.
3
1/4 Flat washer x
.09" thk.
1/4-20 x 1" BHCS (2)
Acu-Rite Companies Inc.