Acu-Tech EFD160 Manuel - Page 4

Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Acu-Tech EFD160. Acu-Tech EFD160 5 pages. Electrofusion drainage welder

Acu-Tech EFD160 Manuel
E0
4. Overvoltage (
)
The input voltage is above 280 volts. Adjust generator output voltage.
5. Temperature Error or Temperature Sensor Defective (
The measured ambient temperature is outside the operating range of the welding unit, i.e., below – 5°C or
over + 40°C.
If this error is displayed during the unit's auto-test, the temperature sensor is defective.
E06
6. Frequency Error (
The frequency of the input voltage is out of tolerance (40 Hz - 70 Hz).
7. Low or Excess Current (
The message is displayed if the there is a momentary current failure or if the current regulator is defective.
E08
8. Emergency Off (
)
The welding process was interrupted by pressing the STOP key.
E09
9. Used Fitting Error (
After welding, the unit was not disconnected from the electrofusion fitting, and the user tried to weld the
same fitting a second time.
E00
10. System Error (
)
Caution: The welding unit must be disconnected immediately from the power supply and the fitting. The
auto-test has found an error in the system. The unit must no longer be operated and has to be turned in
for check and repair.
5. Technical Specifications of the Product
Specification:
Nominal Voltage: 230 V
Frequency: 40 Hz - 70 Hz
Power: 1200 VA, 80 % duty cy.
Ingress Protection: IP 54
Primary Current: Max. 10 A
Ambient Temperature: – 5 °C to + 40 °C
Max. Output Current: 5 A
Tolerances:
Temperature: ± 5 %
Current: ± 2 %
Pursuant to the directive 2002/96/EC on Waste Electrical and Electronic Equipment (so-called WEEE
Directive), equipment that was manufactured or distributed by ourselves may be returned to us. To discuss
the exact procedure we will follow, please contact us with the details below.
We also declare that equipment manufacture complies to the directive 2002/95/EC on the restriction of
the use of certain hazardous substances in electrical and electronic equipment (so-called RoHS Directive).
EFD160 Electrofusion Drainage Welder
)
E07
)
)
Value:
E05
)
Version 1.1
Page 4 of 5