Cisco C880 E7-8800 v3 Manuel d'installation du matériel - Page 17
Parcourez en ligne ou téléchargez le pdf Manuel d'installation du matériel pour {nom_de_la_catégorie} Cisco C880 E7-8800 v3. Cisco C880 E7-8800 v3 31 pages.
2.2
Power cable connection
Input power system of Cisco C880 Server is described in this section.
2.2.1 Power Cables Connections
This section shows the figure of input power of Cisco C880 Server.
Standard Configuration of 200 V (Single power feed and no Redundant Power Feed)
with Power Distribution Box Connection
It is necessary to arrange three PSUs, three FANUs, three power cables (200 V IEC60320 C20) and two
power distribution box (200 V IEC60320 C19×3type) for 200 V standard configuration.
When the power distribution box is used, it is necessary to secure the breaker characteristic of distribution
panel. See
"2.5 Cutoff Characteristics of Distribution Panel (At the time of connecting power distribution
FIGURE 2.9 200V Standard Configuration (single power feed and no redundant power feed) with Power
Number
(1)
Distribution Box Connection
Power distribution box (200V C 19 3 type)
Description
14
box)."