Cisco ONS 15454 Manuel d'instructions d'installation - Page 7

Parcourez en ligne ou téléchargez le pdf Manuel d'instructions d'installation pour {nom_de_la_catégorie} Cisco ONS 15454. Cisco ONS 15454 22 pages. Four-shelf and zero-shelf bay assembly
Également pour Cisco ONS 15454 : Installer (32 pages), Installer (32 pages), Déballage et installation (42 pages), Déballage et installation (40 pages)

Cisco ONS 15454 Manuel d'instructions d'installation
Chapter 2 Install Cards and Fiber-Optic Cable
1. This identifies 1:N cards that operate as normal DS1 or DS3 cards when installed in certain slots.
Stop. You have completed this procedure.
NTP-A16 Install Optical Cards and Connectors
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Warning
During this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not directly
touch the backplane with your hand or any metal tool, or you could shock yourself. Statement 94
Warning
Class I (CDRH) and Class 1M (IEC) laser products. Statement 1055
Invisible laser radiation could be emitted from the end of the unterminated fiber cable or connector.
Warning
Do not stare into the beam directly with optical instruments. Viewing the laser output with certain
optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of
100 mm could pose an eye hazard. Statement 1056
Use of controls, adjustments, or performing procedures other than those specified may result in
Warning
hazardous radiation exposure. Statement 1057
The following warning only applies to OC-192 cards with safety keys.
The laser is on when the card is booted and the safety key is in the on position (labeled 1). The port
Warning
does not have to be in service for the laser to be on. The laser is off when the safety key is off
(labeled 0). Statement 293
78-17697-01
This procedure describes how to install optical cards (OC-3, OC-12,
OC-48, OC-192, MRC-12, and MRC-2.5G-4). The 15454_MRC-12
(multirate), MRC-2.5G-4, OC192SR1/STM64IO Short Reach, and
OC192/STM64 Any Reach (known in CTC as OC192-XFP) cards require
small form-factor pluggables (SFPs/XFPs) to provide the fiber interface to
the cards. On all other optical cards, the fiber is plugged directly into the
card. Install according to site plan, if available.
OC-3, OC-12, OC-48, OC-192, MRC-2.5G-4, and MRC-12 cards (as
applicable)
NTP-A15 Install the Common Control Cards, page 2-2
As needed
Onsite
None
NTP- A16 Install Optical Cards and Connectors
Cisco ONS 15454 Procedure Guide, R8.0
2-7