Cisco UCS C220 M3 Manuel de configuration - Page 14
Parcourez en ligne ou téléchargez le pdf Manuel de configuration pour {nom_de_la_catégorie} Cisco UCS C220 M3. Cisco UCS C220 M3 33 pages. Security manager 4.3
Également pour Cisco UCS C220 M3 : Manuel de démarrage rapide (29 pages), Manuel de mise à jour (10 pages), Manuel de démarrage rapide (12 pages)
Step 4: To create a RAID volume based on a single drive group (RAID 0, 1, 5, or 6), select the required physical
drives and create a drive group with those physical drives. Here are some examples:
●
RAID 0 requires at least one physical drive. If the minimum drive requirement is not met, the Create Virtual
Drive button will not be enabled.
●
RAID 1 requires a minimum of two physical drives in a drive group. If this minimum requirement is not met,
the Create Virtual Drive button will not be enabled.
◦
© 2014 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public.
When only one physical drive is selected, the Create Virtual Drive button is dimmed.
Page 14 of 33