10. Install diff user (2) - Note: remove tape from diff user prior to installing dif-
fuser. Starting at one end of housing, insert diff user slot onto edge of housing.
Carefully squeeze diff user to engage opposite side with housing. Continue this
action down length of diff user until fully installed onto housing.
11. If installing additional satellite units, proceed to follow the Row Connector
Method instructions.
12. If installing only one fi xture - turn on electricity at fuse or circuit breaker box
and verify success of installation.
Row Connector Method
Note: this is for linked satellite units after the main unit is already
installed via the Direct-Wire Method
1.
Remove diff user (2) from housing (1) – locate removal tape attached to
diff user near one end of housing; grasp tape and pull upward to release diff user
from housing. Carefully remove diff user from housing. -See Fig 1
2.
Locate the hardware pack– Check that all parts are included. See Page 3.
Note: Toggle bolts or wood screws are not included.
Warning: Safely dispose of packaging materials.
Assistance may be required to support fi xture during installation.
3.
Remove 4 keyhole knockouts. -See Fig 5
To remove knockouts: Place standard screwdriver on center of slot and gently
strike with hammer. Grip edge with pliers and fl ex back and forth until re-
moved. -See Fig 2
4.
Remove the port covers (9) on the end caps where the connection will be
made.
5.
With the power turned off , insert Row Connector (8) into the previously
installed fi xture and connect next Fixture Housing (1) to connector. While support-
ing housing – mark the screw hole locations to be located at the narrow section
of the keyholes further from the fi rst fi xture (4 total). -See Fig 5.
Note: Fixture orientation is important- make sure all the linked fi xtures are oriented
the same way by checking that the switches (5) are on the same side. The Row
connector must connect to a Keyed port (6) on one fi xture and to a non-keyed
port (7) on the other fi xture. See Figures 6 & 7
6.
Remove the Fixture Housing (1) and using a drill with a 1/16" drill bit, make 4
small pilot holes at the marked screw hole locations. If drill bit does not encounter
a stud or wood surface, use toggle bolts or other suitable fasteners depending on
structural conditions. If drill bit does encounter wood surface, use wood screws.
7.
Partially install the mounting screws. Position the Fixture Housing against
the mounting surface with the screw heads through the keyhole mounting holes.
Slide the housing until the Row connector is securely connecting the two fi xtures
and the screw heads are through the narrow section of the key holes. Finish
tightening the screws to secure the housing.
8.
Install diff user (2) - Note: remove tape from diff user prior to installing dif-
fuser. Starting at one end of housing, insert diff user slot onto edge of housing.
Carefully squeeze diff user to engage opposite side with housing. Continue this
action down length of diff user until fully installed onto housing.
9.
If there are more fi xtures to be connected, mount the remaining fi xture(s)
as stated in the steps 1-8 in this section. Once all fi xtures have been installed
– reinstall port covers on any open ports.
Note: Max of 6 fi xtures can be linked on a single row.
10. Turn on electricity at fuse or circuit breaker box and verify success of installation.
Continue to Page 8
Page 6
Screw Hole Location
Keyhole Knockouts
Figure 5
Figure 6