[NOTE] It is recommended to use a length range within 15~50m
network cable. If the CAT6 cable is too short, there may be no display
output because of the signal is too strong. If the CAT6 cable is too
long,the output may be with poor quality.
4. IR User Guide
4.1 IR blaster extension cable should plug in the IR OUT port of
TX(Sender) of HDMI extender, and the IR receiver extension cable
should plug in the IR IN port of the RX (receiver) unit.
4.2 The emitter of IR blaster should as close as possible to the IR
receiver window of the signal source device.
4.3 Using the IR remote controller of the signal source device towards
the IR receiver (connected to the RX), to remote control source
media playback.
5. EDID Setting
5.1 First of all, set the resolution mode of the source device; please
choose "AUTO" of theresolution mode. (However, when the
resolution mode of your source device is"AUTO" already, and the
output resolution (for instance, output is 720p) is still not in accord
with the resolution that set by the EDID dip switch (for instance, it is
1080p). At this time, please set the resolution of your device again to
make it in accord with the resolution that set by the EDID dipSwitch
(e.g. 1080p)
5.2 HDMI source device reads the EDID information of the transmitter (TX)
and then output the Relative HDMI signal forma
5.3 It needs to power on again or reset the transmitter unit after
re-setting EDID every time
5.4 When connect a TV with loop-out HDMI port of transmitter (TX), it
can adjust EDID switch to read and save this TV's EDID information.
When we use this function, it should connect TV with transmitter
first, and then power on these devices, so that the EDID will be read
and saved successfully. At next time, even though do not connect a
TV into the loop-out HDMIPort, the source device will output the
saved EDID information last time.