50 mm SlimLine Half Coupler 100 kg

Installation

Remove all packing materials from the 50 mm SlimLine Half Coupler. Check if all foam and plastic
padding is removed.
Damages caused by non-observance are not subject to warranty.

Set Up and Operation

Follow the directions below, as they pertain to your preferred operation mode.

Inspection Before First Use

Before the first use of the 50 mm SlimLine Half Coupler, it needs to be inspected by a competent person,
in order to rule out any damage sustained during transport or storage. This should happen at least once a
year.
When installing the Half Coupler, the user must make sure that the Half Coupler is operated in a safe way.
The strength and suitability of the suspension point should be checked in advance.
Before each use, the Half Coupler has to be inspected on the following points:
Overall operation of the Half Coupler itself
Mounting of the Half Coupler onto the structure
Make sure that the Half Coupler shows no trace of visual defects

Installing the Half Coupler

01) Loosen the Half Coupler by turning the spindle counterclockwise
02) Open the Half Coupler.
03) Place the Half Coupler upon the tube.
04) Close and manually tighten the Half Coupler by turning the spindle clockwise. Do not exceed the
recommended tightening torque: 30 N-m (22lb-ft).
05) Make sure that the Half Coupler entirely encompasses the tube.
06) Place the load. When used with other accessories, make sure that the maximum SWL of any
component is not exceeded.
07) It is not recommended to use couplers which do not entirely encompass the tube for overhanging.
All open clamps should be used in a vertical orientation only.
Ordercode: 75001S/75001B
CAUTION
Before installation, operators must be instructed and
fully understand the safe use of the equipment.